Section III. PRINCIPLES OF OPERATION<br />

1-12. SYSTEM DESCRIPTION.<br />

a. To provide NBC protection, a higher pressure must exist inside the shelter than outside the shelter. The airflow<br />

that causes the pressure must pass through the HSFC. Small leaks in the shelter liner will have no effect as long as<br />

pressure is maintained inside shelter.<br />

b. When the system is pressurized, almost all airflow into shelter will flow through PE to the contaminated exterior.<br />

c. The blower inflates the shelter to a pressure of 0.6 iwg. Vents between shelter and PE are adjusted for pressure<br />

of 0.6 iwg in shelter, and vents between PE and outside are adjusted for pressure of 0.25 iwg in PE. Clean air flowing<br />

from shelter to outside through PE purges toxic vapors from PE.<br />

1-13. FUNCTIONAL DESCRIPTION OF MAJOR COMPONENTS.<br />

a. Motor Blower. The blower provides a minimum of 200 cubic feet of air per minute to the protective shelter<br />

through the HSFC. It will operate on 1<strong>10</strong>/220 VAC 50/60 Hz. Blower assembly provides electrical power for extension<br />

light and PE dome light through output connector J2 to the PE power supply.<br />

b. Hermetically Sealed Filter Canister (!SFC). This filter removes toxic chemical agents, biological agents, and<br />

radioactive particles from air passing through it.<br />

c. Air Ducts. The air ducts provide airflow path for air from blower through HSFC into shelter.<br />

d. Recirculation Filter. The recirculation filter removes residual toxic agents which may be present inside the<br />

SCPE liners. The recirculation filter blower motor operates from any 115 VAC 50/60 Hz electrical source.<br />

e. Room Liner. Room liners are cylindrical in shape and are inflated with filtered air from HSFC and blower.<br />

The inflated room liners provide a place to work or rest without having to wear protective clothing.<br />

f. Protective Entrance (PE). PE allows personnel to move from contaminated area into liner without introducing<br />

contaminants into protected area.<br />

g. Differential Pressure Gages. There are two gages that read from 0 iwg to 2.0 iwg. One is mounted on liner<br />

side of PE and measures difference in pressure between inside liner and outside. Another is mounted to inside wall of<br />

PE and measures difference in pressure between inside PE and outside. The gages are used when adjusting internal<br />

pressures in shelter and PE. An adjusting tool is provided to adjust gages before operation.<br />

h. Vents Two vents near the bottom of the two outer PE walls are used to adjust PE pressure. Two vents near the<br />

top of the liner side of PE wall are used to adjust shelter pressure. PE and shelter pressure can be regulated by adjusting<br />

these vents.<br />

i. Dome Light. There is one dome light mounted to the ceiling of the PE which operates at 28 VAC supplied by<br />

PE power supply.<br />

j. Interval Timer. A mechanical five-minute bell timer is mounted on the wall of the PE. It is used to time the<br />

purge period of personnel entering the SCPE from contaminated areas.<br />