TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />
c. PE Exit Procedures.<br />
(1) Exit protective area as follows:<br />
NOTE<br />
For guidance on exit procedures, see FM 34 and unit SOP.<br />
(a)<br />
Look through PE window to ensure PE is unoccupied and interval timer is set at zero. This shows<br />
that the PE has not been occupied and no wait is necessary before entering the PE. Otherwise, wait<br />
until the interval timer bell sounds (about five minutes) before exiting.<br />
(b) Turn interval timer knob to zero (5 minutes). This is to let anyone still inside shelter know when 5-<br />
minute purge time is over.<br />
(2) Exit PE in accordance with FM 3-4 and unit SOP.<br />
2-<strong>10</strong>. OPERATION OF AUXILIARY EQUIPMENT.<br />
WARNING<br />
Locate generator outside structure or in well ventilated area. Do not locate motor blower near an<br />
area where engine exhaust gasses are generated. Filter will not protect against carbon<br />
monoxide. Carbon monoxide poisoning can cause illness, incapacitation, or death to personnel.<br />
a. The SCPE can be operated from a portable generator (App C) when commercial electric power is not available.<br />
Refer to <strong>TM</strong> 5-6115-323-14 for operation of portable generator.<br />
b. Observe the following precautions:<br />
(1) Place portable generator outside building if possible.<br />
(2) If portable generator must be inside structure, place at maximum power cable length from blower.<br />
2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE.<br />
WARNING<br />
SCPE known to be or suspected of biological or chemical agent contamination, must be<br />
decontaminated before striking.<br />
Protective mask and clothing must be worn by personnel handling contaminated components of<br />
SCPE.<br />
2-44