c. PE Exit Procedures.<br />

(1) Exit protective area as follows:<br />

NOTE<br />

For guidance on exit procedures, see FM 34 and unit SOP.<br />

(a)<br />

Look through PE window to ensure PE is unoccupied and interval timer is set at zero. This shows<br />

that the PE has not been occupied and no wait is necessary before entering the PE. Otherwise, wait<br />

until the interval timer bell sounds (about five minutes) before exiting.<br />

(b) Turn interval timer knob to zero (5 minutes). This is to let anyone still inside shelter know when 5-<br />

minute purge time is over.<br />

(2) Exit PE in accordance with FM 3-4 and unit SOP.<br />

2-<strong>10</strong>. OPERATION OF AUXILIARY EQUIPMENT.<br />

WARNING<br />

Locate generator outside structure or in well ventilated area. Do not locate motor blower near an<br />

area where engine exhaust gasses are generated. Filter will not protect against carbon<br />

monoxide. Carbon monoxide poisoning can cause illness, incapacitation, or death to personnel.<br />

a. The SCPE can be operated from a portable generator (App C) when commercial electric power is not available.<br />

Refer to <strong>TM</strong> 5-6115-323-14 for operation of portable generator.<br />

b. Observe the following precautions:<br />

(1) Place portable generator outside building if possible.<br />

(2) If portable generator must be inside structure, place at maximum power cable length from blower.<br />

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE.<br />

WARNING<br />

SCPE known to be or suspected of biological or chemical agent contamination, must be<br />

decontaminated before striking.<br />

Protective mask and clothing must be worn by personnel handling contaminated components of<br />

SCPE.<br />