<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />
2-15. INSTALLING M20A1 SCPE LINERS WITHOUT PRESSURIZATION.<br />
WARNING<br />
This procedure should be done only in a clean environment. Contamination of personnel by<br />
biological or chemical agents can cause serious injury, illness or, death.<br />
NOTE<br />
If room liner is going to be unpressurized for any reason while occupied, use the following steps<br />
to support the liner.<br />
a. Attach support lines (1) across center of room in a cross or "X' pattern at a height of approximately 7 to <strong>10</strong> feet.<br />
b. If only one support line (Item 7, App D) is used, run it from door opening to opposite side of room.<br />
c. Secure all support lines (1) to room walls by any means available.<br />
d. Aline room liner door (2) with room door (3).<br />
e. Attach liner, center row of ties (4), to passive support line (1) going from door opening (3) to opposite side of<br />
room.<br />
f. Attach remaining liner ties (5) to additional support lines (1).<br />
2-65