TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />
Section III.<br />
OPERATION UNDER USUAL CONDITIONS<br />
2-6. INITIAL CONDITION M20AI SCPE.<br />
a. Site Selection. Consider the following conditions when selecting a structure to house an M20A1 SCPE.<br />
(1) Location serves tactical situations.<br />
(2) Location shielded from weapons or blast.<br />
NOTE<br />
Entire M20A SCPE must be deployed indoors.<br />
(3) Location away from low areas where chemical vapors tend to collect.<br />
b. Room Selection.<br />
(1) The M20A1 SCPE should be deployed in a room with four walls, a floor and a ceiling, all in good<br />
condition.<br />
(2) Electrical power available within 25 ft. of chosen room and have at least a 15 Amp circuit breaker.<br />
2-7. INITIAL ADJUS<strong>TM</strong>ENT AND DAILY CHECKS.<br />
Perform before PMCS (para 2-5).<br />
2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE.<br />
a. Preparation.<br />
CAUTION<br />
Hot radiators, heaters, and lights in selected room may damage room liner.<br />
(1) Turn off radiator, heaters, and lights in selected room.<br />
WARNING<br />
Three major components of M20AI SCPE weigh approximately <strong>10</strong>0 pounds each. Lifting and/or<br />
carrying can be accomplished by no fewer than two personnel. Failure to do so can result in<br />
severe injury to personnel.<br />
(2) Carry components of M20Al SCPE (requires two personnel) into selected structure. Place components<br />
near door of selected room.<br />
CAUTION<br />
Debris on floor of selected room may damage room liner.<br />