<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />

(8) From inside room liner (8) have another person aline outer ECU adapter frames (2) with inner frames (3).<br />

(9) From inside room liner (8) tighten four 1/4 turn fasteners (1) on each interface frame through outer ECU<br />

adapter frames (2), room liner (8), and inner ECU adapter frames (3).<br />

(<strong>10</strong>) Using pocket knife (Item 6, App D) cut room liner material (8) from inside both ECU adapter frames (2).<br />

WARNING<br />

Do not operate ECU with ECU make up air ports open. System will become contaminated which<br />

can result in serious illness, injury, or death to personnel.<br />

(11) Close ECU make up air ports.<br />

(12) Operate ECU in accordance with <strong>TM</strong> 5-4120-379-14.<br />