OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20AI SCPE (CONT)<br />
Item Interval Item To Be Procedure Not Fully Mission<br />
No. Check/Service Capable If:<br />
23 After MOTOR BLOWER Check time totalizing meter (I) to see Totalizing meter indicates 550 hours<br />
if 550 hours have passed since last have elapsed since last motor<br />
replaceblower<br />
motor replacement.<br />
ment.<br />
24 After RECIRCULATION NOTE<br />
FILTER<br />
It is vital that recirculation filter for SCPE be fully serviceable.<br />
As an operator you are responsible for notifying unit maintenance<br />
for filter replacement in accordance with filter change criteria<br />
contained in FM 3-4.<br />
a. Check electrical cable (1) for bare Cable has bare wires or broken<br />
wires or broken connector (2) or connector or missing connector or<br />
missing connector or missing missing connector pins.<br />
connector pins (3).<br />
b. Check cover (4), lower case (5), Cover, case, or fan impeller blade<br />
fan impeller blades (6), and guard damage prevents normal operation.<br />
(7) for damage.<br />