f. Installing Recirculation Filter.<br />

(1) Check that recirculation filter power switch (1) is in down (off) position.<br />

(2) Place recirculation filter inside room liner where it will not interfere with personnel movement or restrict<br />

airflow.<br />

CAUTION<br />

To avoid overloading motor blower, do not plug more than one recirculation filter blower into PE<br />

power supply.<br />

(3) Plug recirculation filter power cord (2) into PE power supply.<br />

g. Inflating Room Liner.<br />

(1) Close all vents (1) on PE.<br />