OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)<br />
<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />
Item Interval Item To Be Procedure Not Fully Mission<br />
No. Check/Service Capable If:<br />
15 During GAGES a. Check gages (1) (located on inside Glass is broken, tubing is missing.<br />
and outside wall of PE) for broken<br />
glass (2), and tube (3) is missing.<br />
b. Check that pressure reading in PE Pressure is below 0.2 iwg in PE or<br />
is not below 0.2 iwg.<br />
below 0.4 iwg in liner.<br />
c. Check that pressure reading in<br />
liner is not below 6.4 iwg.<br />
16 During MOTOR BLOWER a. Check for noisy operation. Operating noise level is unusual.<br />
b. Ensure time totalizing meter (1) Time totalizing meter is inoperative.<br />
is operating.<br />
2-16