08.09.2014 Views

TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...

TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...

TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)<br />

<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />

Item Interval Item To Be Procedure Not Fully Mission<br />

No. Check/Service Capable If:<br />

15 During GAGES a. Check gages (1) (located on inside Glass is broken, tubing is missing.<br />

and outside wall of PE) for broken<br />

glass (2), and tube (3) is missing.<br />

b. Check that pressure reading in PE Pressure is below 0.2 iwg in PE or<br />

is not below 0.2 iwg.<br />

below 0.4 iwg in liner.<br />

c. Check that pressure reading in<br />

liner is not below 6.4 iwg.<br />

16 During MOTOR BLOWER a. Check for noisy operation. Operating noise level is unusual.<br />

b. Ensure time totalizing meter (1) Time totalizing meter is inoperative.<br />

is operating.<br />

2-16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!