10.09.2014 Views

Manuals_files/CD Manual 12.pdf - Removable Prosthodontics

Manuals_files/CD Manual 12.pdf - Removable Prosthodontics

Manuals_files/CD Manual 12.pdf - Removable Prosthodontics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Complete Denture Checklist -94<br />

9. Record Bases and Occlusal Rims<br />

! Well adapted to cast with no rocking<br />

! Uniform thickness - about 2 mm.<br />

! Wax rim at level 1/2-2/3 up the retromolar pad; level with corner of mouth anteriorly;<br />

parallel to ala-tragus lines and line between pupils of eyes<br />

! Undercuts blocked out so baseplate does not scrape master cast upon removal<br />

! Peripheries smooth and rounded<br />

! Wax rim centered over ridge (mandibular), slightly facial to ridge (maxillary)<br />

! Labial inclination on anterior portion of wax rim<br />

! Width approximately 7 mm anteriorly and 10 mm posteriorly<br />

! Flat occlusal surface, even contact between rims<br />

! Wax smooth, neat and sealed to base<br />

! Record base well adapted to cast tissue surface<br />

! Infection Control/Other/Other ____________________________<br />

10. Facebow Record (Check prior to removal from patient & prior to mounting)<br />

! Casts properly notched<br />

! Bitefork correctly oriented on occlusal rim and tightened<br />

! Facebow condylar arms properly oriented<br />

! Maxillary cast mounted in same relationship to articulator as maxilla to arbitrary hinge<br />

axis<br />

! Proper anterior reference point used<br />

! Incisal pin correctly oriented<br />

! Cast well united to mounting ring with a smooth neat finish<br />

! Infection Control/Other/Other ____________________________<br />

11. Vertical Dimension<br />

! Palpable closure from physiologic rest to OVD (usually 2-4 mm)<br />

! Interocclusal distance measures 2-4 mm using extraoral marks<br />

! Lips or cheeks do not appear or feel strained<br />

! Phonetics tests ("50`s-60`s" or "Mississippi") - 1mm between rims<br />

! Patient seated upright or standing during vertical dimension evaluation<br />

! Infection Control/Other/Other ____________________________<br />

12. Centric Relation<br />

! Repeatable recording (within constraints of patient)<br />

! Occlusal rim properly reduced for recording medium (2nd PM to 2nd molar)<br />

! Mandibular cast notched and grooves lubricated<br />

! Proper quantity and utilization of medium<br />

! Indices interdigitate accurately<br />

! Horizontal component is correct<br />

! Vertical component is correct<br />

! Cast well united to mounting ring with smooth neat finish<br />

! Casts and/or record bases not touching<br />

! Infection Control/Other/Other ___________________________________

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!