23.10.2014 Views

VnmrJ Command and Parameter Reference VnmrJ 2.2D

VnmrJ Command and Parameter Reference VnmrJ 2.2D

VnmrJ Command and Parameter Reference VnmrJ 2.2D

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A<br />

autolist<br />

autoname<br />

autoname<br />

autora<br />

autosa<br />

autoscale<br />

autostack<br />

autotest<br />

autotime<br />

av<br />

av1<br />

av2<br />

averag<br />

awc<br />

awc1<br />

awc2<br />

axis<br />

axis<br />

axisf<br />

Set up <strong>and</strong> start chained acquisition (M)<br />

Create path for data storage (C)<br />

Prefix for automation data file (P)<br />

Resume suspended automation run (C)<br />

Suspend current automation run (C)<br />

Resume autoscaling after limits set by scalelimits macro (M)<br />

Automatic stacking for processing <strong>and</strong> plotting arrays (M)<br />

Open Auto Test Window (C)<br />

Displays approximate time for automation (M)<br />

Set abs. value mode in directly detected dimension (C)<br />

Set abs. value mode in 1st indirectly detected dimension (C)<br />

Set abs. value mode in 2nd indirectly detected dimension (C)<br />

Calculate average <strong>and</strong> st<strong>and</strong>ard deviation of input (C)<br />

Additive weighting const. in directly detected dimension (P)<br />

Additive weighting const. in 1st indirectly detected dimension (P)<br />

Additive weighting const. in 2nd indirectly detected dimension (P)<br />

Provide axis labels <strong>and</strong> scaling factors (C)<br />

Axis label for displays <strong>and</strong> plots (P)<br />

Axis label for FID displays <strong>and</strong> plots (P)<br />

aa<br />

Syntax:<br />

Description:<br />

See also:<br />

Abort acquisition with error (C)<br />

aa<br />

Aborts an experiment that has been submitted to acquisition. If the experiment<br />

is active, it is aborted immediately, all data is discarded, <strong>and</strong> the experiment is<br />

interpreted as an error. Any data collected from an earlier block size transfer is<br />

retained. If any werr processing is defined, that processing occurs, followed by<br />

any queued experiments. The login name, <strong>and</strong> the FID directory path in file<br />

are used as keys to find the proper experiment to abort.<br />

In some circumstances, there is a delay between the time go is entered <strong>and</strong> the<br />

acquisition is started. During this time, instructions based on the selected pulse<br />

sequence are being generated. This is signified by the letters “PSG” appearing<br />

in the upper left corner of the status window. An aa comm<strong>and</strong> issued under<br />

these circumstances reports that no acquisition is active but it instead stops the<br />

instruction generation process <strong>and</strong> the message “PSG aborted” appears.<br />

NMR Spectroscopy User Guide<br />

Related: file File name of a parameter set (P)<br />

go<br />

Submit experiment to acquisition (C)<br />

halt<br />

Abort acquisition with no error (C)<br />

werr<br />

Specify action when error occurs (C)<br />

werr<br />

When error (P)<br />

abort<br />

Syntax:<br />

Description:<br />

Terminate action of calling macro <strong>and</strong> all higher macros (C)<br />

abort<br />

Terminates the action of the calling macro <strong>and</strong> all higher levels of nested<br />

macros. abort is used only in macros <strong>and</strong> not entered from the keyboard. It<br />

generates an error condition, which is the reason why the calling macro <strong>and</strong> any<br />

01-999380-00 A 0808 <strong>Comm<strong>and</strong></strong> <strong>and</strong> <strong>Parameter</strong> <strong>Reference</strong> for <strong>VnmrJ</strong> <strong>2.2D</strong> 37