Warnings<br />

101. Low-noise signal<br />

102. High-noise signal<br />

103. ADC overflow occurred<br />

104. Receiver overflow occurred*<br />

Soft errors<br />

200. Maximum transient completed for single-precision data<br />

201. Lost lock during experiment (LOCKLOST)<br />

300. Spinner errors:<br />

301. Sample fails to spin after three attempts at repositioning<br />

302. Spinner did not regulate in the allowed time period (RSPINFAIL)*<br />

303. Spinner went out of regulation during the experiment (SPINOUT)*<br />

395. Unknown spinner device specified (SPINUNKNOWN)*<br />

396. Spinner device is not powered up (SPINNOPOWER)*<br />

397. RS-232 cable not connected from console to spinner (SPINRS232)*<br />

398. Spinner does not acknowledge comm<strong>and</strong>s (SPINTIMEOUT)*<br />

400. VT (variable temperature) errors:<br />

400. VT did not regulate in the given time vttime after being set<br />

401. VT went out of regulation during the experiment (VTOUT)<br />

402. VT in manual mode after automatic comm<strong>and</strong> (see Oxford manual)*<br />

403. VT safety sensor has reached limit (see Oxford manual)*<br />

404. VT cannot turn on cooling gas (see Oxford manual)*<br />

405. VT main sensor on bottom limit (see Oxford manual)*<br />

406. VT main sensor on top limit (see Oxford manual)*<br />

407. VT sc/ss error (see Oxford manual)*<br />

408. VT oc/ss error (see Oxford manual)*<br />

495. Unknown VT device specified (VTUNKNOWN)*<br />

496. VT device not powered up (VTNOPOWER)*<br />

497. RS-232 cable not connected between console <strong>and</strong> VT (VTRS232)*<br />

498. VT does not acknowledge comm<strong>and</strong>s (VTTIMEOUT)<br />

500. Sample changer errors:<br />

501. Sample changer has no sample to retrieve<br />

502. Sample changer arm unable to move up during retrieve<br />

503. Sample changer arm unable to move down during retrieve<br />

504. Sample changer arm unable to move sideways during retrieve<br />

505. Invalid sample number during retrieve<br />

506. Invalid temperature during retrieve<br />

507. Gripper abort during retrieve<br />

508. Sample out of range during automatic retrieve<br />

509. Illegal comm<strong>and</strong> character during retrieve*<br />

510. Robot arm failed to find home position during retrieve*<br />

511. Sample tray size is not consistent*<br />

512. Sample changer power failure during retrieve*<br />

513. Illegal sample changer comm<strong>and</strong> during retrieve*<br />

514. Gripper failed to open during retrieve*<br />

515. Air supply to sample changer failed during retrieve*<br />

525. Tried to insert invalid sample number*<br />

526. Invalid temperature during sample changer insert*<br />

527. Gripper abort during insert*<br />

528. Sample out of range during automatic insert<br />

529. Illegal comm<strong>and</strong> character during insert*<br />

530. Robot arm failed to find home position during insert*<br />

531. Sample tray size is not consistent*<br />

532. Sample changer power failure during insert*<br />

533. Illegal sample changer comm<strong>and</strong> during insert*<br />

534. Gripper failed to open during insert*<br />

535. Air supply to sample changer failed during insert*<br />

593. Failed to remove sample from magnet*<br />

594. Sample failed to spin after automatic insert<br />