Dimensioning<br />

Average heating excess temperature for standard floor coverings<br />

Limit curve for<br />

edge areas 15 K<br />

Heat flow density in W/m 2<br />

Limit curve for living<br />

areas 9 K<br />

RI = 0.0 – 0.02 (m 2 .K)/W no covering or tiles<br />

RI = 0.05 (m 2 .K)/W parquet, Melan (melamine resin) and PVC<br />

RI = 0.10 (m 2 .K)/W carpet<br />

RI = 0.15 (m 2 .K)/W deep pile carpet<br />

Excess temperature (K)<br />

Average heating low temperature for room air conditioning<br />

5) Calculation of the flow temperature:<br />

Cooling capacity in W/m 2<br />

t VL<br />

t i<br />

t mH<br />

σ<br />

Example:<br />

Flow temperature (°C)<br />

Room internal temperature (°C)<br />

Heating water excess<br />

temperature (°K)<br />

Temperature Difference<br />

(flow – return flow temperature)<br />

Heating water excess temperature:<br />

t mH<br />

= 18.5 K<br />

Room temperature:<br />

t i<br />

= 20 °C<br />

Temperature Difference:<br />

σ = 5 K<br />

Flow temperature:<br />

t VL<br />

= t i<br />

+ t<br />

σ<br />

mH<br />

+ = 20 + 18.5 +<br />

5<br />

= 41 (°C)<br />

2 2<br />

6) Calculation of the temperature<br />

difference for all other heating circuits<br />

As with the standard room the heating water<br />

excess temperature is calculated using the<br />

specific heating requirement and the pipe<br />

spacing.<br />

The temperature difference is calculated<br />

using this heating water excess temperature<br />

and flow temperature.<br />

Low temperature (K)<br />

7) Border zones<br />

If the heating requirement is not enough<br />

using the maximum floor temperature of<br />

29 °C and the minimum pipe installation<br />

spacing, the calculation for peripheral<br />

zones is required. The calculation uses<br />

a maximum floor temperature of 35 °C in<br />

the peripheral zones to reach the required<br />

heating output. If the minimum pipe spacing<br />

of 100 mm is not sufficient, then flow<br />

temperature is increased for all rooms.<br />

The <strong>system</strong> limits for the design are to<br />

follow.<br />

This flow temperature is valid for all heating<br />

circuits. To apply the correct heat output<br />

to each heating circuit the temperature<br />

difference (flow-return temperature<br />

difference) is varied.<br />

t VL<br />

t i<br />

t mH<br />

σ<br />

Flow temperature (°C)<br />

Room temperature (°C)<br />

Heating water excess<br />

temperature (°K)<br />

Temperature difference<br />

(flow- return temperature difference)<br />

8<br />

Room heating and cooling for floors, walls and ceilings