<strong>XTreme</strong>-<strong>EFIS</strong> Operating Manual Page 15<br />
3.4.4.5 Single fuel flow only indicator<br />
This mode is displayed if either fuel flow 1 or fuel flow 2 is selected and no fuel level senders are selected.<br />
3.4.4.6 Dual fuel flow indicator<br />
This mode is displayed if both fuel flow 1and fuel flow 2 are selected and the fuel mode is selected for dual flow. Both fuel<br />
level senders are disabled.<br />
3.4.4.7 Single tank level indicator<br />
This mode is displayed if either fuel level 1 or fuel level 2 is selected. Both fuel flow senders are disabled.<br />
3.4.4.8 Dual tank level indicator<br />
This mode is displayed if both fuel level 1 and fuel level 2 are selected. Both fuel flow senders are disabled.<br />
3.4.4.9 Differential/Summed fuel flow<br />
This mode is displayed if both fuel flow 1 and fuel flow 2 are selected and the fuel mode is selected for either differential<br />
or summed.<br />
3.4.5 EGT/CHT display section<br />
The <strong>XTreme</strong> supports up to 12 thermocouples for EGTs/CHTs. The EGT/CHT section will<br />
automatically try and maximize the display area according to the number of EGTs/CHTs<br />
selected. The EGT/CHT parameters can be configured in the “EGT SETUP” and “CHT SETUP”<br />
menu.