Chapter 6. Library Stacker Mode<br />

Empty<br />

Cartridge 1<br />

1. DCM inserted with (at least) the top slot left empty. Upon closing the door,<br />

inventory is taken, but no cartridges are moved.<br />

Empty<br />

Empty<br />

Cartridge 2<br />

2. To load a cartridge to Drive 1, open the door for less than<br />

two seconds. Write operation begins.<br />

Note: If the library is powered on after the door is already shut,<br />

the library moves the highest positioned cartridge (not<br />

written to by a previous operation) from the DCM to Drive 1.<br />

Cartridge 14<br />

Cartridge 1<br />

Empty<br />

Cartridge 2<br />

3. When a cartridge is filled and<br />

ejected by the backup script, the<br />

library moves the full cartridge to the<br />

top-most available slot.<br />

Drive Empty<br />

Cartridge 14<br />

Cartridge 1<br />

in drive<br />

Cartridge 14<br />

Drive Empty<br />

Cartridge 1<br />

Empty<br />

Empty<br />

Cartridge 3<br />

Cartridge 14<br />

Cartridge 2<br />

in drive<br />

4. The library moves the highest positioned cartridge not yet written to from<br />

the DCM to drive one. Write operation continues in this manner until...<br />

Cartridge 1<br />

Cartridge 5<br />

Empty<br />

Empty<br />

Cartridge 7<br />

Cartridge 14<br />

Cartridge 6<br />

in drive<br />

5. Write operation completes; to remove the cartridge<br />

from the drive:<br />

- Backup script issues EJECT command OR<br />

- Open the door for less than two seconds.<br />

Cartridges<br />

containing<br />

data from the<br />

operation<br />

Empty<br />

Cartridges<br />

not used<br />

in the<br />

operation<br />

6. Open the door to access the<br />

DCM. Cartridges above the<br />

empty slot contain data from<br />

the operation; those below<br />

the empty slot contain old<br />

data or no data at all.<br />

Drive empty<br />