TELE-X - a Satellite System for TV and Data Communication ...
TELE-X - a Satellite System for TV and Data Communication ...
TELE-X - a Satellite System for TV and Data Communication ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
35<br />
The control individuals are divided into<br />
groups, test batches, which are processed<br />
together as regards statistics,<br />
fault h<strong>and</strong>ling, start <strong>and</strong> stop. The control<br />
individuals are allocated to a batch<br />
by means of comm<strong>and</strong>s.<br />
Fig. 5<br />
LPB 110, central part<br />
FCS File control system<br />
CPEM Control program, editor module<br />
CPAM Control program, analysis module<br />
CREM Comm<strong>and</strong> read file execution module<br />
LOAM Control program, loading module<br />
DDHM Device driver h<strong>and</strong>ler module<br />
CONM Test control module<br />
LINM Linking module<br />
INIM Traffic initiating module<br />
STAM Statistics module<br />
FAUM Fault h<strong>and</strong>ling module<br />
EXCM AX exchange module<br />
ERIOS Ericsson operational system<br />
COMANA Comm<strong>and</strong> analysis module<br />
programs <strong>and</strong> data are associated with<br />
each control individual. However, the<br />
control programs are common <strong>for</strong> a<br />
number of control individuals. Each<br />
type of signalling has its own control<br />
program. The data are specific <strong>for</strong> each<br />
control individual, <strong>and</strong> vary depending<br />
on the type of connection the individual<br />
represents.<br />
For example, the data <strong>for</strong> a local subscriber<br />
line include:<br />
- type of subscriber (A or B)<br />
- subscriber number<br />
- type of dialling tone<br />
- type of ringing control tone<br />
- type of control program.<br />
Within a test batch originating <strong>and</strong> terminating<br />
control individuals can during<br />
traffic be linked either permanently or<br />
dynamically. Permanent linking means<br />
that the control individuals to be linked<br />
are specified in a table, which is set up<br />
by means of comm<strong>and</strong>s. Several different<br />
tables can be set up <strong>and</strong> used in a<br />
given order during the traffic processing.<br />
Dynamic linking means that the<br />
control individuals are linked together<br />
at r<strong>and</strong>om. Atest batch can include control<br />
individuals which belong to several<br />
different signalling systems.<br />
Traffic volume<br />
The traffic volume can be regulated as<br />
follows:<br />
- Even, given by a comm<strong>and</strong><br />
- Poisson distribution<br />
- As much traffic as the connected lines<br />
permit (no traffic regulation).<br />
In each case the number of simultaneous<br />
calls can be preset. The total<br />
number of calls in a test batch is specified<br />
by means of a comm<strong>and</strong>.<br />
Fig. 7<br />
LPB 110, application part<br />
EMBA EM bus adaptation unit<br />
EMHA EM bus h<strong>and</strong>ler module<br />
SLI Subscriber line interface<br />
CCITT 7 Junction lines with CCITT nr 7 signalling<br />
DRIM-LSLI Device driver module <strong>for</strong> local lines<br />
DRIM-7 Device driver module <strong>for</strong> CCITT 7 signalling<br />
DRIM-CALS Device driver module <strong>for</strong> MFC signalling