37<br />

Fig. 10<br />

LPB 110 used in an AXE 10 exchange<br />

Technical data <strong>for</strong> LPB 110<br />

Number of lines<br />

Number of signalling<br />

system types used<br />

simultaneously<br />

Power<br />

Construction<br />

practice<br />

Processor<br />

Programming<br />

language<br />

Operating system<br />

Memory medium<br />

I/O interface<br />

I/O device<br />

Interworking with AX<br />

Comm<strong>and</strong>s<br />

Printouts<br />

Statistics printouts<br />

Signalling systems<br />

=£256<br />

S24<br />

-48 V DC <strong>and</strong> mains<br />

LTR 331<br />

APN 167<br />

ERIPASCAL<br />

ERIOS<br />

514" floppy discs<br />

CCITT V.24<br />

Digital LA 12<br />

(St<strong>and</strong>ard)<br />

CCITT V.24<br />

CCITT MML<br />

Fault printouts<br />

Larm printouts<br />

No. of initiated calls<br />

No. of terminated calls<br />

No. of faults<br />

No. of faults per type<br />

Analog subscriber line<br />

signalling<br />

Line signalling E&M<br />

Register signalling R1,<br />

R2 <strong>and</strong> decadic<br />

CCITT no. 6<br />

CCITT no. 7<br />

PCM 32 <strong>and</strong><br />

24 channels<br />

Starting up<br />

The task of putting LPB 110 into operation<br />

can be divided into a hardware <strong>and</strong><br />

a software stage.<br />

The hardware stage comprises voltage<br />

connection, internal cabling <strong>and</strong> connection<br />

to the test object. The exchange<br />

voltage is connected to the central <strong>and</strong><br />

application parts, <strong>and</strong> mains voltage to<br />

the I/O devices. The internal cabling<br />

consists of bus cabling between the different<br />

units.<br />

The software stage consists of loading<br />

the LPB 110 software from floppy disc<br />

units <strong>and</strong> loading hardware data, control<br />

programs <strong>and</strong> control data.<br />

The hardware data constitute the software<br />

reproduction of the hardware towards<br />

which the programs work. It can<br />

be compared to the exchange data in a<br />

telephone exchange. The data remain<br />

the same as long as no change is made<br />

in the hardware configuration.<br />

The control programs are transcripts of<br />

signalling diagrams <strong>for</strong> the signalling<br />

systems included in LPB 110, <strong>and</strong> are<br />

supplied individually <strong>for</strong> each LPB 110.<br />

If necessary, modifications to control<br />

programs <strong>and</strong> new control programs<br />

can be input direct from the typewriter.<br />

Control data are not supplied with the<br />

equipment but are compiled by the user.<br />

The control data specify, <strong>for</strong> example,<br />

which subjects are to be included in a<br />

test batch, the h<strong>and</strong>ling of fault situations,<br />

the number of connections <strong>and</strong><br />

the type of printouts. The control data<br />

are stored on floppy discs <strong>for</strong> quick<br />

loading when required.<br />

After connection the testing can start.<br />

The start comm<strong>and</strong> is given from the<br />

typewriter or any other I/O device.<br />

LPB110<strong>for</strong>AXE10<br />

LPB 110 is equipped with an interface<br />

<strong>for</strong> connection to the I/O system of<br />

AXE 10 <strong>for</strong> the purpose of testing the<br />

exchange. This means that comm<strong>and</strong>s<br />

can be transmitted from LPB 110, both<br />

manually from the terminal <strong>and</strong> automatically<br />

from user prog rams In the first<br />

case the operator works towards AXE 10<br />

in the same way as from an ordinary<br />

terminal, <strong>and</strong> in the second case user<br />

programs in LPB 110 can, <strong>for</strong> example,<br />

initiate tracing, <strong>and</strong> the result can be<br />

received by <strong>and</strong> utilized in the user program.<br />

<strong>Communication</strong> with LPB 110 can also<br />

take place from a terminal in AXE 10.<br />

This means, <strong>for</strong> example, that LPB110<br />

can be placed at the MDF <strong>and</strong> be operated<br />

by an operator in the control room.<br />

This provides great flexibility in the testing.<br />

Summary<br />

The dem<strong>and</strong> <strong>for</strong> short test times <strong>and</strong><br />

powerful test functions, <strong>and</strong> the trend<br />

towards testing of complete systems<br />

have led to the development of the general<br />

test system LPB 110 <strong>for</strong>the generating<br />

of controlled test traffic. The modular<br />

structure of the system makes it readily<br />

adaptable <strong>for</strong> different applications,<br />

both as regards technology <strong>and</strong> operation.<br />

The system has a wide range of<br />

applications in design, production <strong>and</strong><br />

installation testing.