Fig. 10<br />
LPB 110 used in an AXE 10 exchange<br />
Technical data <strong>for</strong> LPB 110<br />
Number of lines<br />
Number of signalling<br />
system types used<br />
simultaneously<br />
Power<br />
Construction<br />
practice<br />
Processor<br />
Programming<br />
language<br />
Operating system<br />
Memory medium<br />
I/O interface<br />
I/O device<br />
Interworking with AX<br />
Comm<strong>and</strong>s<br />
Printouts<br />
Statistics printouts<br />
Signalling systems<br />
=£256<br />
S24<br />
-48 V DC <strong>and</strong> mains<br />
LTR 331<br />
APN 167<br />
ERIPASCAL<br />
ERIOS<br />
514" floppy discs<br />
CCITT V.24<br />
Digital LA 12<br />
(St<strong>and</strong>ard)<br />
CCITT V.24<br />
CCITT MML<br />
Fault printouts<br />
Larm printouts<br />
No. of initiated calls<br />
No. of terminated calls<br />
No. of faults<br />
No. of faults per type<br />
Analog subscriber line<br />
signalling<br />
Line signalling E&M<br />
Register signalling R1,<br />
R2 <strong>and</strong> decadic<br />
CCITT no. 6<br />
CCITT no. 7<br />
PCM 32 <strong>and</strong><br />
24 channels<br />
Starting up<br />
The task of putting LPB 110 into operation<br />
can be divided into a hardware <strong>and</strong><br />
a software stage.<br />
The hardware stage comprises voltage<br />
connection, internal cabling <strong>and</strong> connection<br />
to the test object. The exchange<br />
voltage is connected to the central <strong>and</strong><br />
application parts, <strong>and</strong> mains voltage to<br />
the I/O devices. The internal cabling<br />
consists of bus cabling between the different<br />
units.<br />
The software stage consists of loading<br />
the LPB 110 software from floppy disc<br />
units <strong>and</strong> loading hardware data, control<br />
programs <strong>and</strong> control data.<br />
The hardware data constitute the software<br />
reproduction of the hardware towards<br />
which the programs work. It can<br />
be compared to the exchange data in a<br />
telephone exchange. The data remain<br />
the same as long as no change is made<br />
in the hardware configuration.<br />
The control programs are transcripts of<br />
signalling diagrams <strong>for</strong> the signalling<br />
systems included in LPB 110, <strong>and</strong> are<br />
supplied individually <strong>for</strong> each LPB 110.<br />
If necessary, modifications to control<br />
programs <strong>and</strong> new control programs<br />
can be input direct from the typewriter.<br />
Control data are not supplied with the<br />
equipment but are compiled by the user.<br />
The control data specify, <strong>for</strong> example,<br />
which subjects are to be included in a<br />
test batch, the h<strong>and</strong>ling of fault situations,<br />
the number of connections <strong>and</strong><br />
the type of printouts. The control data<br />
are stored on floppy discs <strong>for</strong> quick<br />
loading when required.<br />
After connection the testing can start.<br />
The start comm<strong>and</strong> is given from the<br />
typewriter or any other I/O device.<br />
LPB110<strong>for</strong>AXE10<br />
LPB 110 is equipped with an interface<br />
<strong>for</strong> connection to the I/O system of<br />
AXE 10 <strong>for</strong> the purpose of testing the<br />
exchange. This means that comm<strong>and</strong>s<br />
can be transmitted from LPB 110, both<br />
manually from the terminal <strong>and</strong> automatically<br />
from user prog rams In the first<br />
case the operator works towards AXE 10<br />
in the same way as from an ordinary<br />
terminal, <strong>and</strong> in the second case user<br />
programs in LPB 110 can, <strong>for</strong> example,<br />
initiate tracing, <strong>and</strong> the result can be<br />
received by <strong>and</strong> utilized in the user program.<br />
<strong>Communication</strong> with LPB 110 can also<br />
take place from a terminal in AXE 10.<br />
This means, <strong>for</strong> example, that LPB110<br />
can be placed at the MDF <strong>and</strong> be operated<br />
by an operator in the control room.<br />
This provides great flexibility in the testing.<br />
Summary<br />
The dem<strong>and</strong> <strong>for</strong> short test times <strong>and</strong><br />
powerful test functions, <strong>and</strong> the trend<br />
towards testing of complete systems<br />
have led to the development of the general<br />
test system LPB 110 <strong>for</strong>the generating<br />
of controlled test traffic. The modular<br />
structure of the system makes it readily<br />
adaptable <strong>for</strong> different applications,<br />
both as regards technology <strong>and</strong> operation.<br />
The system has a wide range of<br />
applications in design, production <strong>and</strong><br />
installation testing.