esult in a printout <strong>and</strong> are recorded on<br />
counters. After the recording the lines in<br />
question are disconnected unless some<br />
other action has been ordered. Instead<br />
of being disconnected the connection<br />
can be h<strong>and</strong>led as programmed.<br />
Fig. 8<br />
Examples of fault <strong>and</strong> statistics printouts<br />
Fig. 9<br />
Construction practice LTR 331 is used <strong>for</strong> portable<br />
equipement<br />
Start/stop<br />
Start <strong>and</strong> stop can be given <strong>for</strong>:<br />
- control individuals<br />
- test batches<br />
- all programmed <strong>and</strong> open control individuals.<br />
At start up, the system can be ordered to<br />
reset statistics counters <strong>and</strong> fault report<br />
buffers <strong>for</strong> the control individuals being<br />
started. Start <strong>and</strong> stop at preset times<br />
can also be arranged by means of comm<strong>and</strong>s.<br />
Supervision<br />
For LPB110 different types of supervision<br />
are used. The generated traffic, <strong>and</strong><br />
the internal functions are monitored, <strong>for</strong><br />
example the syntax checking of control<br />
programs <strong>and</strong> the monitoring of hardware.<br />
Faults detected during traffic generation<br />
result in fault printouts, <strong>for</strong> example<br />
if a wrong backward signal is received<br />
with MFC signalling or a dialling<br />
tone is not received <strong>for</strong> a local call. In<br />
other cases alarm printouts are initiated.<br />
In LPB110 it is possible to control the<br />
h<strong>and</strong>ling of different fault situations<br />
during the traffic processing. All faults<br />
that are detected during traffic h<strong>and</strong>ling<br />
If a fault is detected in LPB110 a hardware<br />
diagnostic program can be started.<br />
A printout specifies the faulty board.<br />
During the traffic h<strong>and</strong>ling, statistics are<br />
collected per test batch, per control individual<br />
<strong>and</strong> <strong>for</strong> the total amount of traffic.<br />
The statistics can be output by<br />
means of a comm<strong>and</strong>. Periodical statistical<br />
printouts can also be ordered,<br />
fig.8.<br />
Construction practice<br />
The construction practice used <strong>for</strong><br />
LPB 110 is LTR 331, characterized by its<br />
compactness. The system includes two<br />
units, built up of magazines of 12BM<br />
(approx. 50cm wide <strong>and</strong> 25cm high),<br />
the first with one magazine <strong>and</strong> the second<br />
with three stacked magazines,<br />
fig.9.<br />
The top <strong>and</strong> bottom covers are removed<br />
when the unit is used, <strong>and</strong> the resultant<br />
chimney effect ensures good cooling.<br />
Forequipment with very high powerdissipation<br />
a fan unit can be added, which<br />
provides <strong>for</strong>ced cooling.<br />
The equipment is delivered in transport<br />
cases in accordance with the Ericsson<br />
st<strong>and</strong>ard <strong>for</strong> test equipment. The units<br />
are provided with sturdy h<strong>and</strong>les <strong>and</strong><br />
can easily be carried by two men.