(January 2010)<br />

Row<br />

Transmitter, TX3-devise, <strong>for</strong> “multi moment” mode (not yet in production)<br />

1 Devise type [TX3]<br />

1-8 GMT-system time, [yyyy mm dd hh mm ss zzz]<br />

9 NumberOfShots: The total number of transients, NumberOfDatasets *<br />

NumberOfSerie.<br />

10 MomentID: Moment ID in instrument script file<br />

11 DatSeqCount: Dataset counter from TX. Can be match with TIB data.<br />

12 Nplus: The number of positive currents in stack.<br />

13 Nminus: The number of negative currents in stack.<br />

14 VoltageOn: The battery voltage during transmitter on time, [V].<br />

15 VoltageOff: The battery voltage during transmitter off time, [V].<br />

16 TxTemperature: The temperature of the transmitter, [°C].<br />

17 Mean_Current: The mean transmitter current <strong>for</strong> NumberOfSeries. Measured<br />

<strong>for</strong> be<strong>for</strong>e the ramp off, [A]. Current is looped over the NumberOf-<br />

Datasets.<br />

18 Max_Current: The maximum current <strong>for</strong> NumberOfSeries <strong>measurements</strong><br />

[A].<br />

19 Min_Current: The minimum current, <strong>for</strong> NumberOfSeries <strong>measurements</strong>,<br />

[A].<br />

20 RMS_Current: The RMS current <strong>for</strong> NumberOfSeries <strong>measurements</strong>. Not<br />

calculated !<br />