New Jersey Schools Development Authority<br />

Design-Build Performance Specifications<br />

New Caruso Elementary School<br />

Keansburg Public Schools<br />

b. Deflection limits: Ro<strong>of</strong>ing assemblies shall withstand wind and snow loads with<br />

vertical deflections no greater than 1/240 <strong>of</strong> the span.<br />

(1) Provide ro<strong>of</strong>ing assemblies that will sustain the anticipated live load if drainage<br />

is obstructed.<br />

c. Allow for thermal movements resulting from ambient and surface temperature<br />

changes. Base calculations on surface temperatures <strong>of</strong> materials due to both solar<br />

heat gain and nighttime-sky heat loss.<br />

(1) Minimum temperature change (range): 120 deg F (67 deg C), ambient on<br />

material surfaces.<br />

3. Provide minimum design slope <strong>of</strong> ¼” per foot (1:48). To the extent possible, slope ro<strong>of</strong><br />

structure to provide positive drainage under design loading conditions.<br />

E. Weather Resistance<br />

1. General performance: Installed ro<strong>of</strong>ing and base flashings shall withstand specified<br />

uplift pressures, thermally induced movement, and exposure to weather without failure<br />

due to defective manufacture, fabrication, installation, or other defects in construction.<br />

Ro<strong>of</strong>ing and base flashings shall remain watertight.<br />

a. Accelerated weathering: Ro<strong>of</strong>ing system shall withstand 2000 hours <strong>of</strong> exposure<br />

when tested according to ASTM G 152, ASTM G 154, or ASTM G 155.<br />

b. Impact resistance: Ro<strong>of</strong>ing system shall resist impact damage when tested according<br />

to ASTM D 3746 or ASTM D 4272.<br />

F. Durability<br />

1. Life span: In accordance with project requirements and the following:<br />

a. Manufacturer approval <strong>of</strong> design: Where ro<strong>of</strong> covering manufacturer recommends or<br />

requires certain design features for satisfactory performance or for warranty, comply<br />

with manufacturer's requirements.<br />

b. Manufacturer Warranty<br />

(1) Special weathertightness warranty for ro<strong>of</strong>ing system: Manufacturer's standard<br />

form in which manufacturer agrees to repair or replace ro<strong>of</strong> assemblies that fail<br />

to remain weathertight, including leaks, within specified warranty period.<br />

(a) Warranty Period: 20 years from date <strong>of</strong> Substantial Completion.<br />

PRODUCTS<br />

A. Basis <strong>of</strong> Design: SBS Modified Bitumen Multi-Ply Membrane System<br />

1. Provide a complete ro<strong>of</strong>ing assembly including but not limited to ro<strong>of</strong>ing, auxiliary<br />

ro<strong>of</strong>ing materials, substrate board, vapor retarder, insulation, walkway pavers, and all<br />

related accessories.<br />

2. Provide the following:<br />

a. Provide hot-applied SBS modified bitumen multi-ply membrane ro<strong>of</strong>ing system in<br />

compliance with SDA Materials and Systems Standards and the following<br />

requirements.<br />

June 27, 2013 Section B3010.50 Page 2 <strong>of</strong> 3<br />

Low Slope Ro<strong>of</strong>ing