New Jersey Schools Development Authority<br />

Design-Build Performance Specifications<br />

New Caruso Elementary School<br />

Keansburg Public Schools<br />

SECTION C1010.00<br />

INTERIOR PARTITIONS<br />

PERFORMANCE<br />

A. Basic Function<br />

1. Provide physical separation between spaces included in the program, constructed to<br />

achieve fire ratings required by code, appropriate security between adjacent spaces, and<br />

visual, acoustical, olfactory, and atmospheric isolation as necessary to maintain desirable<br />

conditions in each space.<br />

2. Where partition elements also must function as elements defined within another element<br />

group, meet requirements <strong>of</strong> both element groups.<br />

3. Brand Names: Where brand names are listed, they represent the Basis <strong>of</strong> Design unless<br />

those items are identified as approved proprietary items in project requirements.<br />

B. Amenity and Comfort<br />

1. Appearance<br />

a. Provide partitions that are smooth in texture at all circulation routes (SC spaces).<br />

b. Provide operable partitions that are compatible in appearance with fixed partitions in<br />

the same space, employing similar materials, colors, and textures.<br />

2. Health and Safety<br />

a. Fire Resistance: Provide fire ratings as required by code.<br />

b. Sanitation: At spaces used for food preparation, provide smooth, impervious, and<br />

water-resistant partition surfaces and integral coved base that will allow chemical<br />

cleaning and sterilization without damage.<br />

3. Structure<br />

a. Lintels: Constructed to span openings in partitions and support imposed loads with<br />

maximum deflection vertically and horizontally <strong>of</strong> 1/360 <strong>of</strong> span.<br />

b. Vertical Loads: Provide partitions with sufficient strength to withstand anticipated<br />

Code prescribed vertical loads for wall-mounted handrails, equipment, and<br />

furnishings without excessive deflection or structural damage.<br />

c. Horizontal Loads: Provide partitions with sufficient strength and rigidity to withstand<br />

anticipated Code prescribed horizontal loading conditions without excessive<br />

deflection or structural damage.<br />

PRODUCTS<br />

A. Fixed Partitions<br />

1. Construct all partitions in a manner consistent with Materials and Systems Standards and<br />

all project requirements.<br />

June 27, 2013 Section C1010.00 Page 1 <strong>of</strong> 2<br />