– February/March 2011 32<br />

Product News<br />

Incubator with O 2<br />

and N 2<br />

control<br />

The MCO-19M CO 2<br />

incubator provides<br />

extremely accurate control <strong>of</strong><br />

the environment within the incubation<br />

chamber. CO 2<br />

concentration<br />

is measured using a dual infra red<br />

solid state sensor that is not affected<br />

by humidity or temperature changes<br />

when the incubator door is opened. In<br />

addition, the CO 2<br />

sensor remains calibrated<br />

continually without the need<br />

<strong>for</strong> timed recalibration procedures.<br />

O 2<br />

concentration is measured using a solid state zirconium sensor<br />

that is maintenance-free, thereby removing the need <strong>for</strong> constant<br />

recalibration. CO 2<br />

and O 2<br />

levels <strong>are</strong> controlled using a PID controller<br />

to ensure rapid recovery without excessive overshoot <strong>of</strong> the<br />

chosen gas-level set-points. A stable and uni<strong>for</strong>m temperature is<br />

provided within the chamber using Sanyo’s Direct Heat Air Jacket<br />

system, which is PID controlled to ensure rapid recovery after a<br />

door opening. The even distribution <strong>of</strong> temperature throughout<br />

focusonchangeHarrogate International Centre<br />

23–26 May 2011<br />

Harmonisation <strong>of</strong> Blood Sciences<br />

Emerging Technologies<br />

Cancer: Meeting the Needs <strong>of</strong><br />

the Patient<br />

Laboratory Automation<br />

Clinical Biochemistry and the<br />

Coroner<br />

Point <strong>of</strong> C<strong>are</strong> Testing<br />

Clinical Chemistry in the Age<br />

<strong>of</strong> Austerity<br />

Research in Clinical Biochemistry<br />

All day breakfast workshops<br />

www.focus-acb.org.uk<br />

the chamber contributes to the shelf-to-shelf reproducibility <strong>of</strong><br />

conditions. The interior <strong>of</strong> the chamber is manufactured from<br />

InCu saFe, a copper-enriched stainless steel antimicrobial alloy,<br />

which inhibits the growth <strong>of</strong> fungi, mycoplasma and bacteria. For<br />

critical applications the SafeCell UV system automatic decontamination<br />

systems can be incorporated; this optional UV Illuminated<br />

air duct automatically maintains contamination-free air<br />

and humidity within the chamber. For applications which require<br />

additional decontamination, the hydrogen peroxide decontamination<br />

system is extremely effective and fast: a complete cycle only<br />

takes 130 minutes. This system is also safe, since the H 2<br />

O 2<br />

vapour<br />

is contained within the incubator and is broken down to water and<br />

oxygen at the end <strong>of</strong> the cycle. The door interlock and alarm also<br />

ensure that the system is safe.<br />

Sanyo BiomedicaL<br />

Etten-Leur, The Netherlands<br />

www.cli-online.com & search 25512<br />

Midkine ELISA<br />

Midkine (MK) — also<br />

known as neurite growth<br />

promoting factor 2<br />

(NEGF-2) — is a cytokine<br />

that is expressed during<br />

embryonic development.<br />

In healthy adults MK is<br />

expressed at only low levels.<br />

However, MK levels <strong>are</strong> found to be elevated in the blood and<br />

urine <strong>of</strong> patients with carcinomas including oesophageal, stomach,<br />

colon, pancreatic, thyroid, lung, urinary, hepatocellular, neuroblastoma,<br />

glioblastoma, and Wilm´s tumour. MK levels can be<br />

measured in the early stage <strong>of</strong> <strong>cancer</strong> development, making MK<br />

an optimal marker <strong>for</strong> screening and preventive healthc<strong>are</strong>. The<br />

determination <strong>of</strong> MK in blood even detects organ-located solid<br />

tumour malignancy. High MK levels <strong>are</strong> associated with poor<br />

prognosis in some types <strong>of</strong> <strong>cancer</strong>. The combination <strong>of</strong> MK detection<br />

together with established oncologic markers improves <strong>cancer</strong><br />

diagnosis. The Human Midkine ELISA kit extends BioVendor’s<br />

portfolio <strong>of</strong> diagnostic kits <strong>for</strong> oncology. Suitable <strong>for</strong> serum and<br />

plasma samples, the 96 well-microtitre plate <strong>for</strong>mat is suitable <strong>for</strong><br />

use with standard ELISA equipment or robotic systems.<br />

Biovendor<br />

Modrice, The Czech Republic<br />

www.cli-online.com & search 25511<br />

Clinical chemistry analyser<br />

Designed <strong>for</strong> small- to mid-sized<br />

hospitals and laboratories, the<br />

BioMajesty 6010 is a very compact<br />

fully automatic chemical<br />

analyser which can handle up to<br />

1200 tests per hour. With 43 reagents<br />

and 84 sample positions,<br />

it provides the flexibility needed<br />

<strong>for</strong> routine use. Both photometric<br />

and immunoturbidimetric<br />

assays can be per<strong>for</strong>med as well as Na, K and Cl electrolyte<br />

determination using indirect ISE methods. Special emphasis has<br />

been given to the s<strong>of</strong>tw<strong>are</strong>, which combines a high degree <strong>of</strong> user