16.11.2014 Views

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mode of Operation of the <strong>Generator</strong><br />

Thermo-switch at exhaust connection<br />

If the impeller pump should fail, the raw<br />

water stream fed here tears off and the<br />

exhaust connection heats up immediately<br />

extremely fast, since the water cooling is<br />

missing. The thermo-switch supervises a<br />

functioning raw water cycle.<br />

98°C/83°C<br />

Fig. A.2: Thermo-switch at exhaust connection<br />

Thermo-switch in the generator coil<br />

1<br />

2<br />

3<br />

1. <strong>Generator</strong> coil<br />

2. Thermo-switch 4x160°C<br />

3. Housing<br />

For the protection of the generator coil<br />

there are two thermo-switches inside the<br />

coil, which are for inserted parallel and<br />

safety's sake independently from each<br />

other.<br />

Fig. A.3: Coil thermo-switch<br />

Thermo-switch at the front plate<br />

The generator bearing is equipped with an<br />

oil thermoswitch, which switches the<br />

engine off if the oil temperature becomes<br />

to high.<br />

120°C<br />

Fig. A.4: Thermo-switch at front plate<br />

Page 6<br />

<strong>Panda</strong> <strong>PMS</strong> 8 "mini" E-<strong>TEC</strong> s00585 - Chapter A: Mode of Operation of the <strong>Generator</strong>