Maintenance Instructions<br />

B.9.1 Measures on preparation of the winter storage (cont.)<br />

12.During the winter storage the upper section of the sound cover must be taken off, in order to<br />

avoid condensed moisture formation, if traces of humidity remain in the sound cover inside<br />

casing by leakages in the raw water circuit.<br />

13.The generator housing and the housing of the engine should be sprayed with a corrosion protection<br />

oil before the winter storage. This procedure is recommended also in the season. This<br />

procedure can avoid that arising and humidity marks on the surface of the aluminum construction<br />

units be noticed too late.<br />

14.Disconnect the starter battery (positive and negative pole).<br />

15.Lubricate the spindle for the number of revolutions adjustment device with a special lubricant<br />

(Antiseize grease).<br />

16.Check cooling water connection block at the generator housing on traces of corrosion and if<br />

necessary renew. (only such traces are to be considered, which refer to clear "blossoming" of<br />

the material. If the surface is only grey coated, this is only an indication for the fact that aluminum<br />

came into contact with condensed moisture.)<br />

17.Use of a air dehumidifier. The best way to protect a yacht in the winter storage against<br />

damage by humidity is, to places a air dehumidifier inside the ship and locks all hatches. The<br />

devices have a hygrometer, which switches the device off, if the humidity is under the adjusted<br />

value. There is no better method, in order to protect pads, cable, electronics, wood, engines<br />

etc. optimally against any rotting by humidity.<br />

B.9.2 Initiation at spring<br />

• Before the first start turn the engine once with the hand, in order to eliminate necessary existing<br />

corrosion beginnings in the bushing. If necessarily carry out normal engine inspection.<br />

• Change engine oil and engine oil filters.<br />

• Reintegrate the impeller of the cooling water pump and check pump for leakage.<br />

• Charge starter battery of the generator, connect cables and check battery voltage.<br />

• Start generator and check the basic adjustments of the generator such as voltage, speed regulation<br />

etc..<br />

• Check all switching off devices for function by operational procedures.<br />