16.11.2014 Views

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

Marine Generator Panda PMS 8 „mini“ E-TEC Icemaster Fischer ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mode of Operation of the <strong>Generator</strong><br />

A.1.2 Overloading of engine during longer operation<br />

Please ensure that the genset is not overloaded. Overloading occurs when the electrical load<br />

(demand) induces a load torque in the generator which is higher than that which the diesel drive<br />

motor can provide. Overloading causes the engine to run rough, burn oil, creates excessive<br />

exhaust (environmentally unfriendly) and even to stall. Extra caution should be practised with<br />

multi-power units (single and 3-phase current generation) to avoid overloading the diesel drive<br />

engine.<br />

The generator should only be loaded at the peak<br />

rated power for short periods only! A high peak<br />

current is required to start many electrical<br />

devices, especially electric motors and compressors<br />

(from a still stand state).<br />

The height of the rated output (P) can taken from<br />

the identification plate attached on the housing.<br />

In order to guarantee a long life span, the continuous<br />

load should not exceed 80% of the nominal<br />

load. By continuous output we understand the<br />

continuous operation of the generator over many<br />

hours. It is harmless for the engine to supply for<br />

2-3 hours the full rated output.<br />

The total conception of the <strong>Panda</strong> generator guarantees that the continuous load operation does<br />

not release superelevated temperatures of the engine also with extreme conditions. It is to be<br />

considered that the exhaust gas values in the full load operation become more unfavorable (soot<br />

formation).<br />

A.1.3 Use the fuel purge switch S2 for fuel delivery<br />

Switch on the "Stand by"-switch at the<br />

control panel. Functional elements must<br />

shine.<br />

Press „Fuel purge“-switch S2 (located at<br />

the air suction housing) and hold. The<br />

electrical fuel pump must run audibly. The<br />

pressing of the switch become audible<br />

switching on and off of the fuel solenoid<br />

valve at the generator (with removed<br />

sound cover).<br />

Page 10<br />

<strong>Panda</strong> <strong>PMS</strong> 8 "mini" E-<strong>TEC</strong> s00585 - Chapter A: Mode of Operation of the <strong>Generator</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!