Maintenance Instructions<br />

B.4.2 Exchange of the fuel filter<br />

The exchange of the filter depends on the<br />

contamination of the fuel, should take<br />

place at least all 300 operation hours.<br />

Before the exchange of the filter the inlet<br />

must be clamped.<br />

Remove the hoses from the used filter and<br />

fasten them to the new filter. The arrow on<br />

the filter housing indicates the direction of<br />

the fuel flow. A clogged filter causes a<br />

decreased power output of the generator.<br />

B.4.3 Exchange the air filter<br />

Open the air suction housing by loosen the<br />

six screws on the housing cover.<br />

Change the air filter mat<br />

Page 20<br />

<strong>Panda</strong> <strong>PMS</strong> 8 "mini" E-<strong>TEC</strong> s00585 - Chapter B: Maintenance Instructions