<strong>Generator</strong> Failure<br />

10<br />

1. Adjusting screw for upper limitation<br />

2. Speed regulator lever<br />

2<br />

This adjustment should not be changed,<br />

otherwise the warranty expires.<br />

1<br />

C.3.2 Adjustment of the normal speed limitation<br />

Adjusting the lower limitation:<br />

1. Disconnect the plug at the electrical supply line of the actuator.<br />

2. Unclamp the countering nuts with two wrench SW 14.<br />

3. Connect an electrical voltage instrument (voltmeter) with a display range until 300V AC to AC<br />

outlet in the elektrical cabinet.<br />

4. Be sure that no electrical load is adjusted.<br />

5. Start the generator.<br />

6. Decrease the rev of the generator by turning the spindle of the actuator manually until the voltmeter<br />

reach a value of 230V.<br />

7. Both nuts must be screwed tight.<br />

8. Check again if the lower voltage of the generator is limited to min. 230V without load.<br />

Adjusting the upper limitation:<br />

1. Proceed like before and tighten the countering nuts at a voltage of max. 270V without load.<br />

2. Check again if the upper voltage of the generator is limited to this value.<br />

14<br />

1. Adjusting nut for upper speed limitation<br />

2. Adjusting nut for lower speed limitation<br />

1 2<br />

Page 34<br />