Mode of Operation of the <strong>Generator</strong><br />

A.7 Operation of the generator with installation over the waterline<br />

<strong>Generator</strong> over the waterline:<br />

If the generator is installed over the waterline, a stronger impeller wear is possible, the pump can<br />

run after the start some seconds dry.<br />

It is very important that the impeller is exchanged every few months. When starting the generator<br />

attention should be always paid and heard to it, when raw water withdraws from the exhaust<br />

neck. If this takes longer than 5 seconds the impeller must exchanged, he sucks in air before raw<br />

water reaches the impeller (see picture below) and the impeller then wears strongly. In this case<br />

the impeller loses his effect and raw water can penetrate into the engine as well as substantially<br />

destroy it. If the impeller is not exchanged early enough, the entire pump must be replaced.<br />

Otherwise the impeller wings breaks in pieces and it stresses some time to remove these again.<br />

Replacement impeller should always be on board.<br />

With the installation of the generator it must be paid attention that the impeller pump is well<br />

accessible, since the impeller is a wearing part. If this place at the location can be reached not<br />

well, an external pump with electric drive can be used instead of the pump built firmly in the sound<br />

cover, which should be installed in a well accessible place.<br />

1<br />

1. Raw water filter<br />

2. Water cock<br />

3. Hull inlet<br />

Make certain that the raw water<br />

filter lies above the water level,<br />

otherwise with cleaning water<br />

can penetrate by the hull inlet.<br />

An external pre-pump can<br />

relieve the impeller.<br />

2<br />

3<br />

Page 14<br />

<strong>Panda</strong> <strong>PMS</strong> 8 "mini" E-<strong>TEC</strong> s00585 - Chapter A: Mode of Operation of the <strong>Generator</strong>