(2) Harvest Pump Timer, "G" Control Board<br />
<strong>KM</strong>-320MAH-E and <strong>KM</strong>-<strong>650MAH</strong>-E Auxiliary Code U-1 and Later<br />
<strong>KM</strong>-515MAH-E Auxiliary Code U-2 and Later<br />
Factory set for proper operation. Do not adjust. Depending on the harvest pump timer<br />
setting, the pump motor energizes and runs the last 0 or 50 seconds of harvest. The<br />
water valve is energized during harvest for a maximum of 6 minutes or the length<br />
of harvest minus 0 or 50 seconds (determined by the harvest pump timer setting),<br />
whichever is shorter. NOTICE! Do not adjust S4 dip switch 7 out of the factory<br />
default position on this model. This dip switch must be left in the factory default<br />
position or this icemaker will not operate correctly.<br />
"G" Control Board<br />
S4 Dip Switch Setting Pump Motor<br />
No. 7 Time (seconds)<br />
ON 50<br />
OFF 0<br />
f) Factory Use (S4 dip switch 8)<br />
Factory set for proper operation. Do not adjust. This must be left in the factory default<br />
position.<br />
g) Freeze Timer (S4 dip switch 9 & 10)<br />
NOTICE<br />
Adjust to proper specification, or the icemaker may not operate correctly.<br />
The freeze timer setting determines the maximum allowed freeze time to prevent<br />
possible freeze-up issues. Upon termination of the freeze timer, the control board initiates<br />
the harvest cycle. After 2 consecutive timer terminations, the control board shuts the<br />
icemaker down. In this case, see "IV.F.3. Low Ice Production" for possible solutions.<br />
The freeze timer is factory set and no adjustment is required.<br />
S4 Dip Switch Setting Time<br />
No. 9 No. 10 (minutes)<br />
OFF OFF 60<br />
OFF ON 50<br />
ON OFF 70<br />
ON ON 75<br />
27