No Ice Production - Possible Cause<br />
14. Compressor a) Compressor relay/magnetic contactor contacts bad or coil winding<br />
open.<br />
b) Start capacitor or run capacitor defective.<br />
c) Internal protector open.<br />
d) Start relay contacts bad or coil winding open.<br />
e) Compressor defective.<br />
15. Hot Gas Valve a) Closed in harvest cycle.<br />
b) Open in freeze cycle.<br />
16. Thermistor<br />
a) Loose, disconnected, or defective.<br />
See "IV.E. Thermistor Check"<br />
17. Pump Motor a) Motor winding open.<br />
b) Bearing worn out or locked rotor.<br />
c) Defective capacitor.<br />
d) Mechanical seal worn out.<br />
18. Thermostatic Expansion Valve a) Bulb loose.<br />
b) Operating erratically.<br />
19. Liquid Line Valve<br />
a) Closed in freeze cycle.<br />
(<strong>KM</strong>-515MAH-E)<br />
b) Open in harvest cycle.<br />
20. Fan Motor a) Motor winding open.<br />
b) Bearing worn out or locked rotor.<br />
c) Defective capacitor.<br />
21. Water System a) Water leaks causing short freeze time.<br />
2. Freeze-Up<br />
Defrost and clean the icemaker prior to diagnosing freeze-up. See "VI.A. Cleaning and<br />
Sanitizing Instructions." Fill out a freeze-up checklist. The freeze-up checklist can be found<br />
in the <strong>Hoshizaki</strong> America Technician's Pocket Guide or contact your local distributor for a<br />
copy of the freeze-up checklist.<br />
Freeze-Up - Possible Cause<br />
Harvest Cycle<br />
1. Evaporator a) Scaled up.<br />
b) Damaged.<br />
2. Cube Guides a) Out of position.<br />
b) Damaged.<br />
3. Spray Tubes and/or Spray a) Dirty.<br />
Guides<br />
b) Out of position.<br />
4. Water Supply a) Low water pressure.<br />
b) External water filters clogged.<br />
c) Insufficient water line size.<br />
Minimum 1/4" Nominal ID (6 mm Nominal OD in the EU) water<br />
tubing or equivalent.<br />
5. Inlet Water Valve a) Screen or orifice clogged.<br />
b) Defective.<br />
47