No Ice Production - Possible Cause<br />

14. Compressor a) Compressor relay/magnetic contactor contacts bad or coil winding<br />

open.<br />

b) Start capacitor or run capacitor defective.<br />

c) Internal protector open.<br />

d) Start relay contacts bad or coil winding open.<br />

e) Compressor defective.<br />

15. Hot Gas Valve a) Closed in harvest cycle.<br />

b) Open in freeze cycle.<br />

16. Thermistor<br />

a) Loose, disconnected, or defective.<br />

See "IV.E. Thermistor Check"<br />

17. Pump Motor a) Motor winding open.<br />

b) Bearing worn out or locked rotor.<br />

c) Defective capacitor.<br />

d) Mechanical seal worn out.<br />

18. Thermostatic Expansion Valve a) Bulb loose.<br />

b) Operating erratically.<br />

19. Liquid Line Valve<br />

a) Closed in freeze cycle.<br />

(<strong>KM</strong>-515MAH-E)<br />

b) Open in harvest cycle.<br />

20. Fan Motor a) Motor winding open.<br />

b) Bearing worn out or locked rotor.<br />

c) Defective capacitor.<br />

21. Water System a) Water leaks causing short freeze time.<br />

2. Freeze-Up<br />

Defrost and clean the icemaker prior to diagnosing freeze-up. See "VI.A. Cleaning and<br />

Sanitizing Instructions." Fill out a freeze-up checklist. The freeze-up checklist can be found<br />

in the <strong>Hoshizaki</strong> America Technician's Pocket Guide or contact your local distributor for a<br />

copy of the freeze-up checklist.<br />

Freeze-Up - Possible Cause<br />

Harvest Cycle<br />

1. Evaporator a) Scaled up.<br />

b) Damaged.<br />

2. Cube Guides a) Out of position.<br />

b) Damaged.<br />

3. Spray Tubes and/or Spray a) Dirty.<br />

Guides<br />

b) Out of position.<br />

4. Water Supply a) Low water pressure.<br />

b) External water filters clogged.<br />

c) Insufficient water line size.<br />

Minimum 1/4" Nominal ID (6 mm Nominal OD in the EU) water<br />

tubing or equivalent.<br />

5. Inlet Water Valve a) Screen or orifice clogged.<br />

b) Defective.<br />