D. Float Switch Check and Cleaning<br />

F/S is used to determine that there is sufficient water in the water tank after the 1‐minute<br />

fill cycle and after each harvest cycle. F/S is also used to determine that the appropriate<br />

volume of water has been converted into ice before switching out of the freeze cycle. No<br />

adjustment is required.<br />

1. Float Switch Check<br />

To check F/S, follow the steps below.<br />

1) Remove the front panel. Move the control switch to the "OFF" position, then unplug the<br />

icemaker from the mains socket.<br />

2) Remove the base cover, then disconnect one end of the pump tubing to drain the water<br />

tank. See Fig. 3. After the water tank has drained, reconnect the pump tubing.<br />

3) Remove the control box cover.<br />

4) Disconnect the black F/S connector from<br />

CB K5 (black) connector.<br />

5) Check for continuity across F/S leads. With<br />

the water tank empty, F/S should be open.<br />

If open, continue to step 7. If closed, follow<br />

the steps in "IV.D.2. Float Switch Cleaning."<br />

After cleaning F/S, check it again. Replace<br />

if necessary.<br />

Disconnect This<br />

End of Pump<br />

Tubing to Drain<br />

Water Tank<br />

6) Reconnect the black F/S connector, then<br />

replace the control box cover in its correct Base Cover<br />

Fig. 3<br />

position.<br />

7) Plug the icemaker back into the mains socket, then move the control switch to the "ICE"<br />

position. Replace the front panel in its correct position. After 1 minute, the 1-minute fill<br />

cycle should end and the initial harvest cycle should begin. If the initial harvest cycle<br />

begins, F/S is good and the check is complete. If the initial harvest cycle does not<br />

begin, continue to step 9.<br />

8) Remove the front panel. Move the control switch to the "OFF" position, then unplug the<br />

icemaker from the mains socket.<br />

9) Remove the control box cover.<br />

10) Disconnect the black F/S connector from CB K5 (BLACK) connector.<br />

11) Check for continuity across F/S leads. With the water tank full, F/S should be closed. If<br />

F/S is closed and the icemaker will not switch from the 1-minute fill cycle to the initial<br />

harvest cycle, replace CB.<br />

If F/S is open, confirm that the water tank is full. If the water tank is not full, check<br />

the water supply, water filters, and inlet water valve. If the water tank is full, follow the<br />

steps in "IV.D.2. Float Switch Cleaning." After cleaning F/S, check it again. Replace if<br />

necessary.<br />