D. Float Switch Check and Cleaning<br />
F/S is used to determine that there is sufficient water in the water tank after the 1‐minute<br />
fill cycle and after each harvest cycle. F/S is also used to determine that the appropriate<br />
volume of water has been converted into ice before switching out of the freeze cycle. No<br />
adjustment is required.<br />
1. Float Switch Check<br />
To check F/S, follow the steps below.<br />
1) Remove the front panel. Move the control switch to the "OFF" position, then unplug the<br />
icemaker from the mains socket.<br />
2) Remove the base cover, then disconnect one end of the pump tubing to drain the water<br />
tank. See Fig. 3. After the water tank has drained, reconnect the pump tubing.<br />
3) Remove the control box cover.<br />
4) Disconnect the black F/S connector from<br />
CB K5 (black) connector.<br />
5) Check for continuity across F/S leads. With<br />
the water tank empty, F/S should be open.<br />
If open, continue to step 7. If closed, follow<br />
the steps in "IV.D.2. Float Switch Cleaning."<br />
After cleaning F/S, check it again. Replace<br />
if necessary.<br />
Disconnect This<br />
End of Pump<br />
Tubing to Drain<br />
Water Tank<br />
6) Reconnect the black F/S connector, then<br />
replace the control box cover in its correct Base Cover<br />
Fig. 3<br />
position.<br />
7) Plug the icemaker back into the mains socket, then move the control switch to the "ICE"<br />
position. Replace the front panel in its correct position. After 1 minute, the 1-minute fill<br />
cycle should end and the initial harvest cycle should begin. If the initial harvest cycle<br />
begins, F/S is good and the check is complete. If the initial harvest cycle does not<br />
begin, continue to step 9.<br />
8) Remove the front panel. Move the control switch to the "OFF" position, then unplug the<br />
icemaker from the mains socket.<br />
9) Remove the control box cover.<br />
10) Disconnect the black F/S connector from CB K5 (BLACK) connector.<br />
11) Check for continuity across F/S leads. With the water tank full, F/S should be closed. If<br />
F/S is closed and the icemaker will not switch from the 1-minute fill cycle to the initial<br />
harvest cycle, replace CB.<br />
If F/S is open, confirm that the water tank is full. If the water tank is not full, check<br />
the water supply, water filters, and inlet water valve. If the water tank is full, follow the<br />
steps in "IV.D.2. Float Switch Cleaning." After cleaning F/S, check it again. Replace if<br />
necessary.<br />