3. Low Ice Production<br />
Low Ice Production - Possible Cause<br />
Long Harvest Cycle<br />
1. Evaporator a) Scaled up.<br />
2. Spray Tubes and/or Spray<br />
Guides<br />
a) Dirty.<br />
b) Out of position.<br />
3. Refrigerant Charge a) Low.<br />
4. Water Supply a) Low water pressure.<br />
b) External water filters clogged.<br />
c) Insufficient water line size.<br />
Minimum 1/4" Nominal ID (6 mm Nominal OD in the EU) water<br />
tubing or equivalent.<br />
d) Too cold.<br />
5. Control Board<br />
See "IV.B. Control Board Check"<br />
a) Thermistor connection loose (K3).<br />
b) Defective.<br />
6. Thermistor<br />
a) Loose, disconnected, or defective.<br />
See "IV.E. Thermistor Check"<br />
7. Hot Gas Valve a) Erratic or closed.<br />
8. Inlet Water Valve a) Screen or orifice clogged.<br />
9. Compressor a) Inefficient or off.<br />
10. Liquid Line Valve<br />
a) Erratic or open.<br />
(<strong>KM</strong>-515MAH-E)<br />
11. Thermostatic Expansion Valve a) Defective.<br />
Long Freeze Cycle<br />
1. Evaporator a) Scaled up, dirty.<br />
2. Float Switch<br />
a) Scaled up, dirty.<br />
See "IV.D. Float Switch Check b) Float sticking.<br />
and Cleaning"<br />
c) Defective switch.<br />
3. Inlet Water Valve a) Leaking by.<br />
4. Hot Gas Valve a) Erratic or open.<br />
5. Condenser a) Clogged.<br />
6. Control Board<br />
See "IV.B. Control Board Check"<br />
a) Float switch connection loose (K5).<br />
b) Defective.<br />
7. Refrigerant Charge a) Low.<br />
8. Thermostatic Expansion Valve a) Bulb loose.<br />
b) Defective.<br />
9. Compressor a) Inefficient or off.<br />
10. Pump Motor a) RPM too slow.<br />
11. Liquid Line Valve<br />
a) Erratic or restricted.<br />
(<strong>KM</strong>-515MAH-E)<br />
49