F. Diagnostic Charts<br />

1. No Ice Production<br />

No Ice Production - Possible Cause<br />

1. Power Supply a) Off, blown fuse, or tripped breaker.<br />

b) Not within specifications.<br />

2. Fuse (Power Cord) a) Blown.<br />

3. Main Transformer<br />

a) Coil winding open or shorted.<br />

(230VAC/115VAC)<br />

4. Fuse (Control Box) a) Blown.<br />

5. Thermostatic Bin Control a) Tripped with bin filled with ice.<br />

(<strong>KM</strong>-320MAH-E and<br />

b) Ambient temperature too cool.<br />

<strong>KM</strong>‐<strong>650MAH</strong>-E<br />

c) Set too warm.<br />

Aux. Code U-0 and Earlier;<br />

<strong>KM</strong>-515MAH-E<br />

d) Bulb out of position.<br />

Aux. Code U-1 and Earlier) e) Open contacts, defective.<br />

See "IV.C. Bin Control Check"<br />

6. Control Switch a) In "OFF" or "WASH" position.<br />

b) Bad contacts.<br />

7. High-Pressure Switch a) Dirty condenser.<br />

b) Fan motor not operating.<br />

c) Refrigerant overcharged.<br />

d) Bad contacts.<br />

e) Refrigerant lines or components plugged.<br />

8. Control Transformer<br />

a) Coil winding open or shorted.<br />

(115VAC/10.5VAC)<br />

9. Control Board<br />

a) In alarm.<br />

See "IV.B. Control Board Check" b) Yellow "BC OPEN" LED on (bin full).<br />

c) Defective.<br />

10. Mechanical Bin Control a) Tripped with bin filled with ice.<br />

(<strong>KM</strong>-320MAH-E and<br />

b) Actuator does not move freely.<br />

<strong>KM</strong>‐<strong>650MAH</strong>-E<br />

c) Defective.<br />

Aux. Code U-1 and Later;<br />

<strong>KM</strong>-515MAH-E<br />

Aux. Code U-2 and Later)<br />

See "IV.C. Bin Control Check"<br />

11. Water Supply a) Water supply off or improper water pressure.<br />

b) External water filters clogged.<br />

12. Inlet Water Valve a) Screen or orifice clogged.<br />

b) Coil winding open.<br />

c) Water valve open in freeze cycle.<br />

13. Float Switch<br />

a) Float does not move freely.<br />

See "IV.D. Float Switch Check b) Defective.<br />

and Cleaning"<br />

46