23.11.2014 Views

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Reverse Acting Shut-Off Valve Type U<br />

Reverse Acting Shut-Off Valve Type U<br />

3<br />

Order Key<br />

Material: AISI 316L for all wetted parts AL6XN and other high alloys available.<br />

AISI 304L for all non-wetted parts<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

Control Air Pressure: Standard 87 PSI.g<br />

Max Holding Pressure: 116 PSI.g (1"), 87 PSI.g (1.5" to 2"), 72 PSI.g (2.5" to 6") using Standard Actuator<br />

Other pressures available – see section 8.2, chart 2a<br />

Cv Values<br />

(flow in US-gall./min at 1 PSI.g pressure drop)<br />

Valve Size I-II I-IV IV-I VI-I<br />

1" OD 18 11 13 30<br />

1.5" OD 51 28 35 78<br />

3<br />

<strong>GEA</strong> <strong>Tuchenhagen</strong> | 866.531.5629 | www.tuchenhagen.us<br />

40<br />

2. Housing Combinations<br />

3. Stroke Length<br />

R Regular Stroke<br />

4. Valve Size<br />

1" 1.5" 2" 2.5" 3" 4" 6" M: Mix Match – see section 8.4<br />

5. Actuator Type<br />

C Air/Spring Normally Closed O Air/Spring Normally Open A Air/Air<br />

6. Seal Material<br />

E EPDM V FKM H HNBR Other options available.<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

7. Connection Type<br />

T <strong>Tri</strong>-Clamp B Butt Weld* *Applied to all ports unless otherwise specified.<br />

Other process connections available.<br />

8. Port Orientation Upper to Lower Housings<br />

L0 Clamped<br />

VI 0°<br />

V2 0°<br />

V3 0°<br />

V0 Welded Vertical Port<br />

9. Internal Surface Finish<br />

2 30-35 Ra, external matte 4 15-20 Ra, external matte<br />

6 20-25 Ra, external matte 8 15-20 Ra, external polish<br />

U LL - R - 2 - C - E T - L0 - 4 /12 -<br />

Order Key (Std)<br />

11 12 13 14 15 16<br />

0 0 0 0 0 Z<br />

Add Order Key for Control Module<br />

when required (section 8.3)<br />

1 2 3 4 5 6 7 8 9 10 11 - 16<br />

Valve<br />

Type<br />

Housing<br />

Type<br />

Viewed from<br />

actuator end<br />

LL<br />

TT<br />

Stroke<br />

Length<br />

LR<br />

Valve<br />

Size<br />

Actuator<br />

Type<br />

Order key given in short form and will differ from factory-issued documents.<br />

B<br />

C<br />

A<br />

Seal Connect<br />

Material Type<br />

E<br />

F<br />

Port<br />

Orient<br />

D<br />

Finish<br />

90°<br />

F or D Concentric = FC or DC<br />

F or D Eccentric = FX or DX<br />

D Eccentric + Tangential = FLX<br />

F Eccentric + Tangential Right = FXR<br />

F Eccentric + Tangential Left = FXL<br />

Special<br />

Options<br />

180°<br />

270°<br />

Control Module<br />

upper<br />

housing<br />

lower<br />

housing<br />

10. Available Special Accessories / Documentation<br />

/E /12 /20 /21 /24 /25 /43 /50 /67 /41 /42 /BP /BPX<br />

See section 8 for description of accessories and 1.1 for documentation.<br />

11 - 16. Control Module<br />

(see section 8.3)<br />

2" OD 112 33 53 165<br />

2.5" OD 198 64 99 254<br />

I<br />

III<br />

3" OD 309 79 109 413<br />

4" OD 633 160 208 798<br />

6" OD<br />

Weights<br />

Valve Size<br />

Dimensions<br />

Valve<br />

Size<br />

OD in accordance with ASME-BPE-a-2004, DIN 11866, Row C<br />

K H<br />

Ø<br />

Ø A P K S C Ø1 H Stroke<br />

1.0" OD 1 x 0.063 1.81 7.87 1.89 0.08 3.54 2.76 11.61 0.87<br />

1.5" OD 1.5 x 0.063 2.32 7.87 2.15 0.08 3.54 3.35 12.68 0.98<br />

2.0" OD 2 x 0.063 2.81 7.87 2.38 0.08 3.54 3.35 12.91 1.1<br />

2.5" OD 2.5 x 0.063 3.54 9.06 2.95 0.12 4.92 4.49 13.58 1.14<br />

3.0" OD 3 x 0.063 4.06 9.06 3.21 0.12 4.92 4.49 13.70 1.22<br />

4.0" OD 4 x 0.078 5.02 9.84 3.69 0.12 4.92 6.06 15.20 1.14<br />

6.0" OD<br />

lbs.<br />

1" OD 21<br />

1.5" OD 21<br />

2" OD 26<br />

2.5" OD 37<br />

3" OD 55<br />

4" OD 59<br />

6" OD<br />

P = Clearance required for maintenance<br />

II<br />

IV<br />

Recommended flow<br />

direction to prevent<br />

pressure surges during<br />

the closing operation<br />

of the valve.<br />

P<br />

D<br />

K<br />

C<br />

Add 1.1" to Dimension C for<br />

<strong>Tri</strong>-Clamp Connections<br />

Ø<br />

A<br />

Ø1<br />

Housing combination<br />

style UF/UD for tank<br />

inlet applications.<br />

S<br />

www.tuchenhagen.us | 866.531.5629 | <strong>GEA</strong> <strong>Tuchenhagen</strong><br />

41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!