23.11.2014 Views

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

H<br />

X<br />

H<br />

X<br />

Mixproof Bottom Valve Type T<br />

Mixproof Bottom Valve Type T<br />

Order Key<br />

Material: AISI 316L for all wetted parts (housing ASME BPE) AL6XN and other high alloys available.<br />

AISI 304L for all non-wetted parts<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

Control Air Pressure:<br />

Max Holding Pressure:<br />

Standard 87 PSI.g<br />

87 PSI.g (1.5" to 2"), 72 PSI.g (2.5" to 4") using Standard Actuator<br />

Other pressures available – contact <strong>GEA</strong> <strong>Tuchenhagen</strong><br />

Weld jig<br />

recommended<br />

for housing<br />

type U or T.<br />

Ku<br />

with housing connection U<br />

Øu<br />

Kt<br />

with housing connection T<br />

Øt<br />

5<br />

2. Housing Combinations<br />

with housing connection T<br />

L<br />

T<br />

with housing connection U<br />

F<br />

D<br />

Cv Values<br />

(flow in US-gall./min at<br />

1 PSI.g pressure drop)<br />

Ø<br />

Valve Size I-II III-I<br />

C<br />

Cavity Flush<br />

GPM*<br />

C1<br />

K 1<br />

Ø1<br />

Ø<br />

*<br />

C<br />

C1<br />

Ø1<br />

K1<br />

5<br />

3. Mixproof Options<br />

N Without Seat Lift See T_L for Seat Lift Options, page 70<br />

1.5" OD 57 38 2.0<br />

2" OD 104 43 2.0<br />

4. Valve Size<br />

2.5" OD 117 69 2.1<br />

1.5" 2" 2.5" 3" 4"<br />

3" OD 204 103 2.1<br />

5. Actuator Type<br />

C Air/Spring Normally Closed G Manual with Interlock<br />

D<br />

4" OD 407 174 2.1<br />

III<br />

D<br />

<strong>GEA</strong> <strong>Tuchenhagen</strong> | 866.531.5629 | www.tuchenhagen.us<br />

68<br />

6. Seal Material<br />

E EPDM V FKM H HNBR Other options available.<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

7. Connection Type<br />

T <strong>Tri</strong>-Clamp B Butt Weld* *Applied to all ports unless otherwise specified.<br />

Other process connections available.<br />

8. Port Orientation Upper to Lower Housings<br />

L0<br />

Clamped<br />

9. Internal Surface Finish<br />

2 30-35 Ra, external matte 4 15-20 Ra, external matte<br />

6 20-25 Ra, external matte 8 15-20 Ra, external polish<br />

T L - N - 2.5 - G - V B - L0 - 8 /50 -<br />

Order Key (Std)<br />

11 12 13 14 15 16<br />

0 0 0 0 0 Z<br />

Add Order Key for Control Module<br />

when required (section 8.3)<br />

1 2 3 4 5 6 7 8 9 10 11 - 16<br />

Valve<br />

Type<br />

Housing<br />

Type<br />

Mixproof<br />

Options<br />

Valve<br />

Size<br />

Actuator<br />

Type<br />

Order key given in short form and will differ from factory-issued documents.<br />

10. Available Special Accessories / Documentation<br />

/E /25 /32 /36 /43 /50 /67 /41 /42 /BP /BPX<br />

See section 8 for description of accessories and 1.1 for documentation.<br />

Seal Connect<br />

Material Type<br />

Port<br />

Orient<br />

Finish<br />

Special<br />

Options<br />

11 - 16. Control Module<br />

(see section 8.3)<br />

Control Module<br />

I<br />

Weights<br />

Valve Size<br />

Dimensions<br />

Valve<br />

Size<br />

lbs.<br />

1.5" OD 35<br />

2" OD 56<br />

2.5" OD 63<br />

3" OD 82<br />

4" OD 123<br />

OD in accordance with ASME-BPE-a-2004, DIN 11866, Row C<br />

Ø Ø1 Øt Øu C C1 D H Kt Ku K1 X Stroke<br />

1.5" OD 1.5 x 0.063 0.91 x 0.059 6.50 3.35 x 0.079 3.54 3.54 4.29 21.46 2.13 2.15 3.31 4.92 0.87<br />

2.0" OD 2 x 0.063 0.91 x 0.059 6.50 3.35 x 0.079 3.54 3.54 4.29 21.73 2.40 2.42 3.54 4.92 1.22<br />

2.5" OD 2.5 x 0.063 1.14 x 0.059 7.87 4.49 x 0.098 3.54 3.54 5.31 22.20 2.87 2.95 3.78 4.92 1.22<br />

3.0" OD 3 x 0.063 1.14 x 0.059 7.87 4.49 x 0.098 4.92 3.54 6.69 24.41 3.15 3.23 4.02 4.92 1.54<br />

4.0" OD 4 x 0.078 1.14 x 0.059 8.86 6.06 x 0.079 4.92 3.54 6.69 24.37 3.62 3.72 4.13 4.92 1.61<br />

X = Clearance required for maintenance<br />

II<br />

Add 1.1" to Dimension C<br />

for <strong>Tri</strong>-Clamp Connections<br />

* Cavity Cleaning:<br />

Hose connection<br />

for 1" OD<br />

for 1.5" - 4" OD<br />

Ø 6/4 mm<br />

Ø 8/6 mm<br />

Recommended operating pressure<br />

for optimal cleaning efficiency:<br />

36 PSI.g Min., 72 PSI.g Max.<br />

www.tuchenhagen.us | 866.531.5629 | <strong>GEA</strong> <strong>Tuchenhagen</strong><br />

69

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!