Leak Free Mixproof Valve Type R_L with Lifting Actuator<br />
Leak Free Mixproof Valve Type R_L with Lifting Actuator<br />
Order Key<br />
Material: AISI 316L for all wetted parts (housing ASME BPE) AL6XN and other high alloys available.<br />
AISI 304L for all non-wetted parts<br />
Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />
Control Air Pressure:<br />
Standard 87 PSI.g<br />
Cv Values<br />
(flow in US-gall./min at 1 PSI.g pressure drop)<br />
Valve Size I-II I-III III-IV III-I<br />
Cavity Flush<br />
GPM*<br />
X<br />
Max Holding Pressure:<br />
116 PSI.g (1"), 87 PSI.g (1.5" to 2"), 72 PSI.g (2.5" to 4") using Standard Actuator<br />
Other pressures available – contact <strong>GEA</strong> <strong>Tuchenhagen</strong><br />
1" OD 0.6<br />
1.5" OD 69 16 64 17 2.0<br />
5<br />
2. Housing Combinations<br />
2" OD 138 45 127 45 2.0<br />
5<br />
2.5" OD 228 87 182 83 2.1<br />
3" OD 350 121 282 124 2.1<br />
B<br />
C<br />
A<br />
E<br />
4" OD 681 230 566 230 2.1<br />
D<br />
3. Mixproof Options<br />
<strong>GEA</strong> <strong>Tuchenhagen</strong> | 866.531.5629 | www.tuchenhagen.us<br />
64<br />
L With Seat Lift with lower Balancer C With Seat Lift with lower Balancer<br />
and spray cleaning<br />
without spray cleaning<br />
4. Valve Size<br />
1" 1.5" 2" 2.5" 3" 4" M: Mix Match – limited options available.<br />
Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />
5. Actuator Type<br />
C Air/Spring Normally Closed<br />
6. Seal Material<br />
E EPDM V FKM H HNBR Other options available.<br />
Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />
7. Connection Type<br />
T <strong>Tri</strong>-Clamp B Butt Weld* *Applied to all ports unless otherwise specified.<br />
Other process connections available.<br />
8. Port Orientation Upper to Lower Housings<br />
L0 Clamped<br />
VI 0°<br />
V2 0°<br />
V3 0°<br />
V_ Welded<br />
9. Internal Surface Finish<br />
2 30-35 Ra, external matte 4 15-20 Ra, external matte<br />
6 20-25 Ra, external matte 8 15-20 Ra, external polish<br />
R A - L - 2 - C - V B - V1 - 4 /67 -<br />
Order Key (Std)<br />
11 12 13 14 15 16<br />
0 0 0 0 0 Z<br />
Add Order Key for Control Module<br />
when required (section 8.3)<br />
1 2 3 4 5 6 7 8 9 10 11 - 16<br />
Valve<br />
Type<br />
Housing<br />
Type<br />
Mixproof<br />
Options<br />
Valve<br />
Size<br />
Actuator<br />
Type<br />
Order key given in short form and will differ from factory-issued documents.<br />
Seal Connect<br />
Material Type<br />
Port<br />
Orient<br />
Finish<br />
90°<br />
Special<br />
Options<br />
180°<br />
270°<br />
Control Module<br />
upper<br />
housing<br />
lower<br />
housing<br />
10. Available Special Accessories / Documentation<br />
/E /12 /16 /23 /24 /25 /26 /32 /36 /43 /50 /67 /41 /42 /BP /BPX<br />
See section 8 for description of accessories and 1.1 for documentation.<br />
11 - 16. Control Module<br />
(see section 8.3)<br />
I<br />
III<br />
Weights<br />
Valve Size<br />
Dimensions<br />
Valve<br />
Size<br />
OD in accordance with ASME-BPE-a-2004, DIN 11866, Row C<br />
A H<br />
Ø<br />
K<br />
Ø A C D D1 H K X Stroke<br />
1.0" OD 1 x 0.063 1.81 3.54 4.29 4.29 21.38 3.46 9.84 0.87<br />
1.5" OD 1.5 x 0.063 2.32 3.54 4.29 4.29 21.93 4.72 9.84 0.83<br />
2.0" OD 2 x 0.063 2.81 3.54 4.29 4.29 21.85 5.12 9.84 1.22<br />
2.5" OD 2.5 x 0.063 3.54 4.92 4.29 5.31 23.50 6.34 9.84 1.38<br />
3.0" OD 3 x 0.063 4.06 4.92 4.29 5.31 23.86 6.69 9.84 1.77<br />
4.0" OD 4 x 0.078 5.02 4.92 4.29 6.69 24.13 7.40 9.84 1.77<br />
X = Clearance required for maintenance<br />
II<br />
IV<br />
lbs.<br />
1" OD 23<br />
1.5" OD 32<br />
2" OD 45<br />
2.5" OD 63<br />
3" OD 67<br />
4" OD 91<br />
Add 1.1" to<br />
Dimension C<br />
for <strong>Tri</strong>-Clamp<br />
Connections<br />
D1<br />
C<br />
Recommended flow direction to<br />
prevent pressure surges during<br />
the closing operation of the valve.<br />
* Cavity Cleaning:<br />
Hose connection<br />
for 1" OD<br />
for 1.5" - 4" OD<br />
*<br />
Ø 6/4 mm<br />
Ø 8/6 mm<br />
Recommended operating pressure<br />
for optimal cleaning efficiency:<br />
36 PSI.g Min., 72 PSI.g Max.<br />
www.tuchenhagen.us | 866.531.5629 | <strong>GEA</strong> <strong>Tuchenhagen</strong><br />