23.11.2014 Views

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Divert Valve Accessory Range Type W<br />

Divert Valve Accessory Range Type W<br />

4<br />

Order Key<br />

Material: AISI 316L for all wetted parts AL6XN and other high alloys available.<br />

AISI 304L for all non-wetted parts<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

Control Air Pressure: Standard 87 PSI.g<br />

Max Holding Pressure: 116 PSI.g (1"), 87 PSI.g (1.5" to 2"), 72 PSI.g (2.5" to 6") using Standard Actuator<br />

Other pressures available – see section 8.2, chart 2a<br />

2. Housing Combinations<br />

K<br />

V<br />

P<br />

O W Y U M X N Z G<br />

Cv Values<br />

(flow in US-gall./min at 1 PSI.g pressure drop)<br />

Valve Size I-II I-III III-I III-VII VII-III<br />

1" OD 31 28 29 21 21<br />

1.5" OD 70 28 45 47 52<br />

2" OD 140 44 66 85 77<br />

2.5" OD 236 75 119 129 145<br />

3" OD 305 136 127 161 159<br />

4" OD 606 167 215 289 257<br />

6" OD<br />

H X<br />

D<br />

4<br />

3. Stroke Length<br />

R<br />

Regular Stroke<br />

4. Valve Size<br />

1" 1.5" 2" 2.5" 3" 4" 6" M: Mix Match – see section 8.4<br />

I<br />

II<br />

C<br />

5. Actuator Type<br />

C Air/Spring Normally Closed O Air/Spring Normally Open A Air/Air<br />

III<br />

Ø<br />

<strong>GEA</strong> <strong>Tuchenhagen</strong> | 866.531.5629 | www.tuchenhagen.us<br />

48<br />

6. Seal Material<br />

E EPDM V FKM H HNBR Other options available.<br />

Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />

7. Connection Type<br />

T <strong>Tri</strong>-Clamp B Butt Weld* *Applied to all ports unless otherwise specified.<br />

Other process connections available.<br />

8. Port Orientation Upper to Lower Housings<br />

L0 Clamped<br />

VI 0°<br />

V2 0°<br />

V3 0°<br />

V0 Welded Vertical Port<br />

9. Internal Surface Finish<br />

2 30-35 Ra, external matte 4 15-20 Ra, external matte<br />

6 20-25 Ra, external matte 8 15-20 Ra, external polish<br />

W K - R - 1.5 - C - E T - V0 - 2 /28 -<br />

90°<br />

180°<br />

270°<br />

Order Key (Std)<br />

upper<br />

housing<br />

lower<br />

housing<br />

11 - 16. Control Module<br />

(see section 8.3)<br />

11 12 13 14 15 16<br />

0 0 0 0 0 Z<br />

Add Order Key for Control Module<br />

when required (section 8.3)<br />

1 2 3 4 5 6 7 8 9 10 11 - 16<br />

Valve<br />

Type<br />

Housing<br />

Type<br />

Stroke<br />

Length<br />

Valve<br />

Size<br />

Actuator<br />

Type<br />

Order key given in short form and will differ from factory-issued documents.<br />

10. Available Special Accessories / Documentation<br />

/E /16 /20 /21 /24 /28 /43 /50 /67 /41 /42 /BP /BPX<br />

See section 8 for description of accessories and 1.1 for documentation.<br />

Seal Connect<br />

Material Type<br />

Port<br />

Orient<br />

Finish<br />

Special<br />

Options<br />

Control Module<br />

Weights<br />

Valve Size<br />

Dimensions<br />

Valve<br />

Size<br />

OD in accordance with ASME-BPE-a-2004, DIN 11866, Row C<br />

Ø A B C D H X Stroke<br />

1.0" OD 1 x 0.063 1.81 1.14 3.54 3.86 11.73 7.60 0.28<br />

1.5" OD 1.5 x 0.063 2.32 1.54 3.54 5.31 13.51 7.60 0.87<br />

2.0" OD 2 x 0.063 2.81 1.65 3.54 5.31 13.74 7.60 0.87<br />

2.5" OD 2.5 x 0.063 3.54 2.13 4.92 6.69 15.44 7.60 0.75<br />

3.0" OD 3 x 0.063 4.06 2.13 4.92 6.69 15.71 7.60 0.67<br />

4.0" OD 4 x 0.078 5.02 2.72 4.92 8.27 16.03 7.60 0.87<br />

6.0" OD<br />

VII<br />

lbs.<br />

1" OD 22<br />

1.5" OD 40<br />

2" OD 40<br />

2.5" OD 55<br />

3" OD 55<br />

4" OD 57<br />

6" OD<br />

X = Clearance required for maintenance<br />

A<br />

B<br />

Add 1.1" to Dimensions B and C for<br />

<strong>Tri</strong>-Clamp Connections*<br />

*<strong>GEA</strong> <strong>Tuchenhagen</strong> recommends at least one<br />

process connection for maintenance purposes.<br />

Recommended flow direction to<br />

prevent pressure surges during<br />

the closing operation of the valve.<br />

www.tuchenhagen.us | 866.531.5629 | <strong>GEA</strong> <strong>Tuchenhagen</strong><br />

49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!