VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada
VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada
VESTA GEA Tuchenhagen Pharmaceutical Brochure - Tri-Canada
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Divert Valve Accessory Range Type W<br />
Divert Valve Accessory Range Type W<br />
4<br />
Order Key<br />
Material: AISI 316L for all wetted parts AL6XN and other high alloys available.<br />
AISI 304L for all non-wetted parts<br />
Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />
Control Air Pressure: Standard 87 PSI.g<br />
Max Holding Pressure: 116 PSI.g (1"), 87 PSI.g (1.5" to 2"), 72 PSI.g (2.5" to 6") using Standard Actuator<br />
Other pressures available – see section 8.2, chart 2a<br />
2. Housing Combinations<br />
K<br />
V<br />
P<br />
O W Y U M X N Z G<br />
Cv Values<br />
(flow in US-gall./min at 1 PSI.g pressure drop)<br />
Valve Size I-II I-III III-I III-VII VII-III<br />
1" OD 31 28 29 21 21<br />
1.5" OD 70 28 45 47 52<br />
2" OD 140 44 66 85 77<br />
2.5" OD 236 75 119 129 145<br />
3" OD 305 136 127 161 159<br />
4" OD 606 167 215 289 257<br />
6" OD<br />
H X<br />
D<br />
4<br />
3. Stroke Length<br />
R<br />
Regular Stroke<br />
4. Valve Size<br />
1" 1.5" 2" 2.5" 3" 4" 6" M: Mix Match – see section 8.4<br />
I<br />
II<br />
C<br />
5. Actuator Type<br />
C Air/Spring Normally Closed O Air/Spring Normally Open A Air/Air<br />
III<br />
Ø<br />
<strong>GEA</strong> <strong>Tuchenhagen</strong> | 866.531.5629 | www.tuchenhagen.us<br />
48<br />
6. Seal Material<br />
E EPDM V FKM H HNBR Other options available.<br />
Contact <strong>GEA</strong> <strong>Tuchenhagen</strong>.<br />
7. Connection Type<br />
T <strong>Tri</strong>-Clamp B Butt Weld* *Applied to all ports unless otherwise specified.<br />
Other process connections available.<br />
8. Port Orientation Upper to Lower Housings<br />
L0 Clamped<br />
VI 0°<br />
V2 0°<br />
V3 0°<br />
V0 Welded Vertical Port<br />
9. Internal Surface Finish<br />
2 30-35 Ra, external matte 4 15-20 Ra, external matte<br />
6 20-25 Ra, external matte 8 15-20 Ra, external polish<br />
W K - R - 1.5 - C - E T - V0 - 2 /28 -<br />
90°<br />
180°<br />
270°<br />
Order Key (Std)<br />
upper<br />
housing<br />
lower<br />
housing<br />
11 - 16. Control Module<br />
(see section 8.3)<br />
11 12 13 14 15 16<br />
0 0 0 0 0 Z<br />
Add Order Key for Control Module<br />
when required (section 8.3)<br />
1 2 3 4 5 6 7 8 9 10 11 - 16<br />
Valve<br />
Type<br />
Housing<br />
Type<br />
Stroke<br />
Length<br />
Valve<br />
Size<br />
Actuator<br />
Type<br />
Order key given in short form and will differ from factory-issued documents.<br />
10. Available Special Accessories / Documentation<br />
/E /16 /20 /21 /24 /28 /43 /50 /67 /41 /42 /BP /BPX<br />
See section 8 for description of accessories and 1.1 for documentation.<br />
Seal Connect<br />
Material Type<br />
Port<br />
Orient<br />
Finish<br />
Special<br />
Options<br />
Control Module<br />
Weights<br />
Valve Size<br />
Dimensions<br />
Valve<br />
Size<br />
OD in accordance with ASME-BPE-a-2004, DIN 11866, Row C<br />
Ø A B C D H X Stroke<br />
1.0" OD 1 x 0.063 1.81 1.14 3.54 3.86 11.73 7.60 0.28<br />
1.5" OD 1.5 x 0.063 2.32 1.54 3.54 5.31 13.51 7.60 0.87<br />
2.0" OD 2 x 0.063 2.81 1.65 3.54 5.31 13.74 7.60 0.87<br />
2.5" OD 2.5 x 0.063 3.54 2.13 4.92 6.69 15.44 7.60 0.75<br />
3.0" OD 3 x 0.063 4.06 2.13 4.92 6.69 15.71 7.60 0.67<br />
4.0" OD 4 x 0.078 5.02 2.72 4.92 8.27 16.03 7.60 0.87<br />
6.0" OD<br />
VII<br />
lbs.<br />
1" OD 22<br />
1.5" OD 40<br />
2" OD 40<br />
2.5" OD 55<br />
3" OD 55<br />
4" OD 57<br />
6" OD<br />
X = Clearance required for maintenance<br />
A<br />
B<br />
Add 1.1" to Dimensions B and C for<br />
<strong>Tri</strong>-Clamp Connections*<br />
*<strong>GEA</strong> <strong>Tuchenhagen</strong> recommends at least one<br />
process connection for maintenance purposes.<br />
Recommended flow direction to<br />
prevent pressure surges during<br />
the closing operation of the valve.<br />
www.tuchenhagen.us | 866.531.5629 | <strong>GEA</strong> <strong>Tuchenhagen</strong><br />