Operation<br />
Spray Boom Operation<br />
The RowKING sprayer is normally fitted with a<br />
<strong>Silvan</strong> RowMASTER Vegetable Boom of 12 or 15<br />
metre width. Field operation of the boom is<br />
described below. Refer to the Boom Operators<br />
<strong>Manual</strong> for information on boom safety,<br />
specifications, adjustment and maintenance.<br />
The standard method of boom control is by three<br />
sets of remote outlets on front mounted booms and<br />
two sets on rear mounted booms, using the tractor<br />
levers for the lifting and folding operations<br />
If optional electric-over-hydraulic controls are fitted<br />
only one set of remote hydraulics is required.<br />
Lifting and folding is controlled by the switches on<br />
the cabin box. Three bank controls are needed for<br />
lifting and folding and five bank if the optional outer<br />
wing fold or individual wing tilt is fitted.<br />
Left Tilt<br />
Main Fold<br />
Right Tilt<br />
Outer Fold<br />
Lift Switch<br />
Spare<br />
Switches<br />
Foam<br />
Marker<br />
Switch<br />
Master<br />
On/Off<br />
Switch<br />
ELECTRIC OVER HYDRAULIC BOOM CONTROL BOX<br />
Electric-Over-Hydraulic Boom Controls<br />
<strong>Silvan</strong> electric-over-hydraulic controls enable all<br />
operations to be controlled by one set of tractor<br />
remotes. The lift and fold functions and optional tilt<br />
function, if fitted, are selected by using the<br />
switches of the cabin control to operate solenoid<br />
valves on the sprayer that connect the appropriate<br />
hydraulic circuit.<br />
The control box also incorporates a Master On/Off<br />
switch and a 3-position switch for the optional foam<br />
marker. Two vacant switches are available for<br />
connecting other equipment and the system is<br />
protected by a 10 amp fuse on the rear of the<br />
control box.<br />
To operate the boom, the lever controlling<br />
hydraulic flow to the remote outlet is set to the<br />
open position. The Master switch of the control box<br />
is set to “On” and all further boom movements are<br />
controlled by the switches on the control box.<br />
Raising or lowering the “Lift” switch raises or<br />
lowers the boom. Ensure that the hydraulic hoses<br />
are correctly connected so the boom moves in the<br />
same direction as the switch. The lift hose can be<br />
identified by the tap fitted at its end.<br />
The “Main Fold” switch folds or unfolds both<br />
sections of the boom.<br />
The “Outer Fold” switch folds only the outer section<br />
so that the boom can be used at reduced width.<br />
When this position is selected it is necessary to<br />
stop the outer section from spraying with the<br />
section switches on the Silvamatic control box or<br />
Farmscan controller.<br />
Folding and Unfolding the Boom<br />
Always ensure that the boom is folded or unfolded<br />
in a safe area where it will not foul on any other<br />
objects. Never fold or unfold near overhead power<br />
lines. Ensure that all bystanders are clear and<br />
sound the horn before moving the boom with the<br />
tractor hydraulics.<br />
The speed at which the boom folds or unfolds can<br />
be adjusted, refer to the Boom Operators <strong>Manual</strong><br />
for details.<br />
Unfolding. The arms rest on a resilient pad in a<br />
support saddle on each side of the sprayer and are<br />
not held by any lock mechanism. Before unfolding,<br />
the boom must be raised so the arms can swing<br />
clear of the saddle as the unfolding action occurs.<br />
Use the “Main Fold” switch to unfold the arms. As<br />
the arms unfold the outer section will swing<br />
forward at the hinge, thus straightening the boom.<br />
The boom can now be lowered for operation by<br />
using the “Lift” switch.<br />
Folding<br />
To fold the boom, first raise it to full height to lock it<br />
in the level position by using the “Lift” switch.<br />
Use the “Main Fold” switch to slowly swing the<br />
arms back over the support saddles. As the arms<br />
swing back the outer section will fold back against<br />
the inner section.<br />
When the arms are fully folded use the “Lift” switch<br />
to lower them onto the support saddles. Lower the<br />
boom just sufficiently to rest fully on the saddles.<br />
Check that a spraybar nozzle is not too close to<br />
the saddle as it may be damaged as the boom<br />
slides back and forth on the saddle during<br />
transport over uneven ground. Raising or lowering<br />
the boom slightly whilst folded will alter the position<br />
of the nozzles relative to the saddle.<br />
23