TECHNICAL SPECIFICATION FOR<br />

SDH/PDH Equipment with integrated Access Multiplexer<br />

Synchronization Map<br />

Since this is a large network, to facilitate the identification of synchronization problems<br />

within the communication network, the NMS should provide a dynamic synchronization<br />

view/map. This synchronization view must display the active synchronization sources<br />

<strong>for</strong> every network element using a graphical representation, so the clock distribution in<br />

the network can be easily tracked.<br />

2.6.3.3 Security Management<br />

Access to the different functional areas of the NMS shall be strictly controlled by the<br />

privileges assigned to the individual NMS users. Accounts which shall have access to<br />

the NMS must be assigned NMS access rights by an NMS administrator. There shall<br />

be one overall NMS administrator which is able to create additional regional<br />

administrators which have full control e.g. to assign NMS access rights, but are limited<br />

to their domain – corresponding to e.g. a geographical region.<br />

To simplify the task of access right assignments customer specific user profiles can be<br />

predefined which then can be assigned the individual NMS users. It should allow to<br />

create users which have access rights to several/all domains with a different profile <strong>for</strong><br />

each domain.<br />

Specifically, the following features must be individually assignable to different user<br />

classes and/or user accounts:<br />

• Administrative functions such as adding, modifying and deleting NMS user<br />

accounts<br />

• Different levels of access rights to the network elements (modify, monitor only,<br />

software download)<br />

• Access to individual network elements or groups of network elements (regions)<br />

• The right to create and modify network maps<br />

• Use function such as Alarm Forwarding, Trail Configuration, etc.<br />

2.6.3.4 Per<strong>for</strong>mance Management<br />

Per<strong>for</strong>mance management is concerned with evaluation of the use of network<br />

equipments and their capability to meet per<strong>for</strong>mance objectives. Minimum specific<br />

requirements that shall be satisfied include the following:<br />

a. Provide support <strong>for</strong> an operator to initiate, collect, and terminate per<strong>for</strong>mance<br />

metrics under both normal and degraded conditions. For example, BER of each<br />

link, together with other data measured at each node, shall be available on<br />

operator request.<br />

b. Monitor point to point & end to end signal quality and history. Provide operator<br />

controls to monitor per<strong>for</strong>mance of specified events, measures, and resources.<br />

Specifically provide displays to permit the operator to:<br />

1. Select/deselect network equipments, events, and threshold parameters to monitor<br />

2. Set monitoring start time and duration or end time<br />

3. Set monitoring sampling frequency<br />

4. Set/change threshold values on selected per<strong>for</strong>mance parameters<br />

Sign & Seal of Bidder<br />