SIMATIC S7-<strong>400</strong><br />

Central processing units<br />

© Siemens AG 2008<br />

CPU 414<br />

5<br />

■ Technical specifications (continued)<br />

PROFINET IO controller (cont.)<br />

6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM05-0AB0<br />

• Address area<br />

- Inputs, max. 8 Kibyte<br />

- Outputs, max. 8 Kibyte<br />

- Useful data consistency,<br />

max.<br />

PROFINET CBA<br />

• Acyclic transmission<br />

• cyclic transmission<br />

3rd interface<br />

Type of interfaces<br />

pluggable interface module<br />

Pluggable interface module (IF),<br />

technical specifications as for 2nd<br />

interface<br />

IF 964-DP<br />

(Order No.: 6ES7 964-2AA04-0AB0)<br />

255 byte;<br />

incl. net data accompaniers<br />

Yes<br />

Yes<br />

Pluggable interface module (IF)<br />

IF 964-DP<br />

(Order No.: 6ES7 964-2AA04-0AB0)<br />

Physics<br />

RS 485 / PROFIBUS<br />

isolated<br />

Yes<br />

power supply to interface<br />

150 mA; max. 150 mA<br />

(15 to 30 V DC), max.<br />

Number of connection resources 16<br />

Functionality<br />

•MPI<br />

No<br />

• DP master<br />

Yes<br />

• DP slave<br />

Yes<br />

DP master<br />

• Number of connections, max. 16<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- Global data communication No<br />

- S7 basic communication Yes<br />

- S7 communication Yes<br />

- Equidistance support Yes<br />

- SYNC/FREEZE Yes<br />

- Activation/deactivation of<br />

Yes<br />

DP slaves<br />

- Direct data exchange Yes<br />

• Transmission rate, max.<br />

12 MBit/s<br />

• Number of DP slaves, max. 96<br />

• Address area<br />

- Inputs, max. 6 Kibyte<br />

- Outputs, max. 6 Kibyte<br />

• Useful data per DP slave<br />

- Useful data per DP slave,<br />

244 byte<br />

max.<br />

- Inputs, max. 244 byte<br />

- Outputs, max. 244 byte<br />

- Slots, max. 244<br />

- per slot, max. 128 byte<br />

DP slave<br />

• Number of connections 16<br />

• Services<br />

- Routing Yes<br />

- Status/control Yes<br />

5/18 Siemens ST 70 · 2009