SIMATIC S7-<strong>400</strong><br />
Central processing units<br />
■ Technical specifications (continued)<br />
6ES7 416-2FN05-<br />
0AB0<br />
6ES7 416-3FR05-<br />
0AB0<br />
S7 counter (continued)<br />
• Remanence<br />
- adjustable Yes Yes<br />
- lower limit 0 0<br />
- upper limit 2 047 2 047<br />
- preset From Z 0 to Z 7 From Z 0 to Z 7<br />
• Counting range<br />
- lower limit 0 0<br />
- upper limit 999 999<br />
IEC counter<br />
• present Yes Yes<br />
• Type SFB SFB<br />
S7 times<br />
• Number 2 048 2 048<br />
• Remanence<br />
- adjustable Yes Yes<br />
- lower limit 0 0<br />
- upper limit 2 047 2 047<br />
- preset No times retentive No times retentive<br />
• Time range<br />
- lower limit 10 ms 10 ms<br />
- upper limit 9 990 s 9 990 s<br />
IEC timer<br />
• present Yes Yes<br />
• Type SFB SFB<br />
Data areas and their<br />
remanence<br />
remanent data area, total Total working and<br />
load memory (with<br />
backup battery)<br />
Total working and<br />
load memory (with<br />
backup battery)<br />
Flag<br />
• Number, max. 16 Kibyte 16 Kibyte<br />
• Remanence available Yes Yes<br />
• Number of clock memories 8; (in 1 memory<br />
byte)<br />
Address area<br />
I/O address area<br />
8; (in 1 memory<br />
byte)<br />
• Inputs 16 Kibyte 16 Kibyte<br />
•Outputs 16 Kibyte 16 Kibyte<br />
• of which, distributed<br />
- MPI/DPinterface, inputs 2Kibyte 2Kibyte<br />
- MPI/DP interface, 2Kibyte<br />
2Kibyte<br />
outputs<br />
- DP interface, inputs 8Kibyte 8Kibyte<br />
- DP interface, outputs 8Kibyte 8Kibyte<br />
Process image<br />
• Inputs, adjustable 16 Kibyte 16 Kibyte<br />
• Outputs, adjustable 16 Kibyte 16 Kibyte<br />
• Inputs, preset 512 byte 512 byte<br />
• Outputs, preset 512 byte 512 byte<br />
• consistent data, max. 244 byte 244 byte<br />
• Access to consistent data<br />
in process image<br />
Yes<br />
Yes<br />
6ES7 416-2FN05-<br />
0AB0<br />
CPU 416F<br />
6ES7 416-3FR05-<br />
0AB0<br />
Subprocess images<br />
• Number of subprocess 15 15<br />
images, max.<br />
Digital channels<br />
• Inputs 131 072 131 072<br />
•Outputs 131 072 131 072<br />
• Inputs, of which central 131 072 131 072<br />
• Outputs, of which central 131 072 131 072<br />
Analog channels<br />
• Inputs 8 192 8 192<br />
•Outputs 8 192 8 192<br />
• Inputs, of which central 8 192 8 192<br />
• Outputs, of which central 8 192 8 192<br />
Hardware config.<br />
connectable OPs 63 63<br />
Central devices, max. 1 1<br />
Expansion devices, max. 21 21<br />
Multicomputing<br />
Yes; Max. 4 CPUs<br />
(with UR1 or UR2)<br />
Yes; Max. 4 CPUs<br />
(with UR1 or UR2)<br />
IM<br />
• Number of connectable 6 6<br />
IMs (total), max.<br />
• Number of connectable 6 6<br />
IM 460s, max.<br />
• Number of connectable 4; IM 463-2 4; IM 463-2<br />
IM 463s, max.<br />
Number of DP masters<br />
• integrated 2 2<br />
• via IM 467 4 4<br />
•via CP 10; CP 443-5<br />
Extended<br />
• Mixed mode IM + CP<br />
permitted<br />
No; IM 467 cannot<br />
be used with<br />
CP 443-5 Ext.;<br />
IM 467 cannot be<br />
used with<br />
CP 443-1 EX40 in<br />
PN IO mode<br />
• via interface module 0 1<br />
• Number of pluggable 6 6<br />
S5 modules (via adapter<br />
capsule in central device),<br />
max.<br />
Number of IO controllers<br />
• integrated<br />
•via CP 4;<br />
Via CP 443-1 EX 41<br />
in PN mode; max. 4<br />
in central controller<br />
Number of operable FMs<br />
and CPs (recommended)<br />
•FM<br />
Limited due to<br />
number of slots and<br />
number of connections<br />
10; CP 443-5<br />
Extended<br />
No; IM 467 cannot<br />
be used with<br />
CP 443-5 Ext.;<br />
IM 467 cannot be<br />
used with<br />
CP 443-1 EX40 in<br />
PN IO mode<br />
4;<br />
Via CP 443-1 EX 41<br />
in PN mode; max. 4<br />
in central controller<br />
Limited due to<br />
number of slots and<br />
number of connections<br />
5<br />
Siemens ST 70 · 2009<br />