© Siemens AG 2008<br />
SIMATIC S7-<strong>400</strong><br />
Central processing units<br />
CPU 416<br />
■ Technical specifications (continued)<br />
DP slave (continued)<br />
6ES7 416-2XN05-0AB0 6ES7 416-3XR05-0AB0 6ES7 416-3ER05-0AB0<br />
• Address area, max. 32 32 32; Virtual slots<br />
• Useful data per address area,<br />
max.<br />
• Useful data per address area,<br />
of which consistent, max.<br />
2nd interface<br />
32 byte 32 byte 32 byte<br />
32 byte 32 byte 32 byte<br />
Physics RS 485 / PROFIBUS RS 485 / PROFIBUS Ethernet<br />
isolated Yes Yes Yes<br />
Functionality<br />
• DP master Yes Yes No<br />
• DP slave Yes Yes No<br />
• PROFINET IO controller<br />
• PROFINET CBA<br />
• Point-to-point coupling<br />
DP master<br />
• Number of connections, max. 32 32<br />
• Services<br />
- PG/OP communication Yes Yes<br />
- Routing Yes Yes<br />
- S7 basic communication Yes Yes<br />
- S7 communication Yes Yes<br />
- equidistance support Yes Yes<br />
- Activation/deactivation of Yes<br />
Yes<br />
DP slaves<br />
- direct data exchange<br />
(cross traffic)<br />
Yes<br />
Yes<br />
• Transmission speeds, max. 12 MBit/s 12 MBit/s<br />
• Number of DP slaves, max. 125 125<br />
• Address area<br />
- Inputs, max. 8 Kibyte 8Kibyte<br />
- Outputs, max. 8 Kibyte 8Kibyte<br />
• Useful data per DP slave<br />
- Inputs, max. 244 byte 244 byte<br />
- Outputs, max. 244 byte 244 byte<br />
DP slave<br />
• Number of connections 32 32<br />
• Services<br />
- Routing Yes Yes<br />
- Programming Yes Yes<br />
• GSD file<br />
http://support.automation.siemens.<br />
com/WW/view/en/113652<br />
• Transmission speeds, max. 12 MBit/s 12 MBit/s<br />
• Transfer memory<br />
- Inputs 244 byte 244 byte<br />
-Outputs 244 byte 244 byte<br />
• Address area, max. 32 32<br />
• Useful data per address area,<br />
max.<br />
• Useful data per address area,<br />
of which consistent, max.<br />
PROFINET IO-Controller<br />
32 byte 32 byte<br />
32 byte 32 byte<br />
http://support.automation.siemens.<br />
com/WW/view/en/113652<br />
• Services<br />
- PG/OP communication Yes<br />
- Routing Yes; Routing of PG functions<br />
- S7 communication Yes<br />
- open IE communication Yes<br />
Yes<br />
Yes<br />
No<br />
5<br />
Siemens ST 70 · 2009<br />
5/29