© Siemens AG 2008<br />

SIMATIC S7-<strong>400</strong><br />

Central processing units<br />

CPU 416<br />

■ Technical specifications (continued)<br />

DP slave (continued)<br />

6ES7 416-2XN05-0AB0 6ES7 416-3XR05-0AB0 6ES7 416-3ER05-0AB0<br />

• Address area, max. 32 32 32; Virtual slots<br />

• Useful data per address area,<br />

max.<br />

• Useful data per address area,<br />

of which consistent, max.<br />

2nd interface<br />

32 byte 32 byte 32 byte<br />

32 byte 32 byte 32 byte<br />

Physics RS 485 / PROFIBUS RS 485 / PROFIBUS Ethernet<br />

isolated Yes Yes Yes<br />

Functionality<br />

• DP master Yes Yes No<br />

• DP slave Yes Yes No<br />

• PROFINET IO controller<br />

• PROFINET CBA<br />

• Point-to-point coupling<br />

DP master<br />

• Number of connections, max. 32 32<br />

• Services<br />

- PG/OP communication Yes Yes<br />

- Routing Yes Yes<br />

- S7 basic communication Yes Yes<br />

- S7 communication Yes Yes<br />

- equidistance support Yes Yes<br />

- Activation/deactivation of Yes<br />

Yes<br />

DP slaves<br />

- direct data exchange<br />

(cross traffic)<br />

Yes<br />

Yes<br />

• Transmission speeds, max. 12 MBit/s 12 MBit/s<br />

• Number of DP slaves, max. 125 125<br />

• Address area<br />

- Inputs, max. 8 Kibyte 8Kibyte<br />

- Outputs, max. 8 Kibyte 8Kibyte<br />

• Useful data per DP slave<br />

- Inputs, max. 244 byte 244 byte<br />

- Outputs, max. 244 byte 244 byte<br />

DP slave<br />

• Number of connections 32 32<br />

• Services<br />

- Routing Yes Yes<br />

- Programming Yes Yes<br />

• GSD file<br />

http://support.automation.siemens.<br />

com/WW/view/en/113652<br />

• Transmission speeds, max. 12 MBit/s 12 MBit/s<br />

• Transfer memory<br />

- Inputs 244 byte 244 byte<br />

-Outputs 244 byte 244 byte<br />

• Address area, max. 32 32<br />

• Useful data per address area,<br />

max.<br />

• Useful data per address area,<br />

of which consistent, max.<br />

PROFINET IO-Controller<br />

32 byte 32 byte<br />

32 byte 32 byte<br />

http://support.automation.siemens.<br />

com/WW/view/en/113652<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes; Routing of PG functions<br />

- S7 communication Yes<br />

- open IE communication Yes<br />

Yes<br />

Yes<br />

No<br />

5<br />

Siemens ST 70 · 2009<br />