SIMATIC S7-<strong>400</strong><br />

Central processing units<br />

© Siemens AG 2008<br />

5<br />

CPU 416F<br />

■ Technical specifications (continued)<br />

6ES7 416-2FN05-<br />

0AB0<br />

6ES7 416-3FR05-<br />

0AB0<br />

2nd interface<br />

Physics<br />

RS 485 / PROFIBUS Ethernet<br />

isolated Yes Yes<br />

Functionality<br />

• DP master Yes No<br />

• DP slave Yes No<br />

• PROFINET IO controller<br />

Yes<br />

• PROFINET CBA<br />

Yes<br />

• Point-to-point coupling<br />

No<br />

DP master<br />

• Number of connections, 32<br />

max.<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- S7 basic communication Yes<br />

- S7 communication Yes<br />

- equidistance support Yes<br />

- Activation/deactivation of Yes<br />

DP slaves<br />

- direct data exchange Yes<br />

(cross traffic)<br />

• Transmission speeds, 12 MBit/s<br />

max.<br />

• Number of DP slaves, max. 125<br />

• Address area<br />

- Inputs, max. 8Kibyte<br />

- Outputs, max. 8Kibyte<br />

• Useful data per DP slave<br />

- Inputs, max. 244 byte<br />

- Outputs, max. 244 byte<br />

DP slave<br />

• Number of connections 32<br />

• Services<br />

- Routing Yes<br />

- Programming Yes<br />

• GSD file<br />

http://support.<br />

automation.<br />

siemens.com/WW/<br />

view/en/113652<br />

• Transmission speeds, 12 MBit/s<br />

max.<br />

• Transfer memory<br />

- Inputs 244 byte<br />

-Outputs<br />

244 byte<br />

• Address area, max. 32<br />

• Useful data per address 32 byte<br />

area, max.<br />

• Useful data per address 32 byte<br />

area, of which consistent,<br />

max.<br />

6ES7 416-2FN05-<br />

0AB0<br />

6ES7 416-3FR05-<br />

0AB0<br />

PROFINET IO controller<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes; Routing of PG<br />

functions<br />

- S7 communication Yes<br />

- open IE communication Yes<br />

• Transmission rate, min.<br />

10 MBit/s<br />

• Transmission speed, max.<br />

100 MBit/s<br />

• Total number of<br />

256<br />

connectable IO Devices,<br />

max.<br />

• Updating time<br />

250 μs to 512 ms;<br />

minimum value<br />

dependent on<br />

preset communication<br />

share for<br />

PROFINET I/O,<br />

of number of I/O<br />

devices and<br />

number of<br />

configured user<br />

data<br />

• Address area<br />

- Inputs, max. 8 Kibyte<br />

- Outputs, max. 8 Kibyte<br />

- Useful data consistency,<br />

255 byte; incl. net<br />

max.<br />

data accompaniers<br />

PROFINET CBA<br />

• Acyclic transmission<br />

Yes<br />

• cyclic transmission<br />

Yes<br />

3rd interface<br />

Type of interfaces<br />

Pluggable interface<br />

module (IF),<br />

technical specifications<br />

as for 2nd<br />

interface<br />

pluggable interface module<br />

IF 964-DP<br />

(Order No.: 6ES7<br />

964-2AA04-0AB0)<br />

Physics<br />

RS 485 / PROFIBUS<br />

isolated<br />

Yes<br />

power supply to interface<br />

150 mA<br />

(15 to 30 V DC), max.<br />

Number of connection<br />

32<br />

resources<br />

Functionality<br />

•MPI<br />

No<br />

•DP master<br />

Yes<br />

•DP slave<br />

Yes<br />