BHDV34NA, PA<br />

®<br />

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)<br />

VENTING<br />

INSTALLATION<br />

Continued<br />

Horizontal Termination<br />

Configurations<br />

Figures 16 through 20 show different configurations<br />

for <strong>vent</strong>ing with horizontal termination.<br />

Each figure includes a chart with<br />

vertical minimum/maximum and horizontal<br />

maximum dimensions which must be<br />

met. Seal all connections with high temperature<br />

silicone sealant (outer pipe only) as<br />

specified in the second warning statement<br />

on page 7. All horizontal terminations require<br />

1/4" rise per 12" of horizontal run.<br />

Horizontal Venting<br />

Vertical (V) Horizontal (H)<br />

44" min. 29" max.<br />

(30° and 90° only, no vertical pipe)<br />

55" min. 41" max.<br />

(30° elbow, 1' vertical pipe, 90° elbow)<br />

67" min. 60" max.<br />

79" min. 84" max.<br />

96" min. 20' max.<br />

Note: This configuration for use with<br />

corner installation.<br />

UP<br />

BVK Vent Kit Shown<br />

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One<br />

90° Elbow<br />

UP<br />

Horizontal Venting<br />

BGFVK Vent Kit Shown<br />

(recommended for use<br />

with cabinet mantels)<br />

Horizontal Venting<br />

Vertical (V) Horizontal (H)<br />

37" min. 10" max.<br />

See information in<br />

Figure 17 for<br />

Vertical(V) and<br />

Horizontal(H) maximums<br />

and minimums.<br />

The same amounts<br />

apply for flexible<br />

<strong>vent</strong>ing.<br />

Note: Figure 16<br />

applies to rigid<br />

<strong>vent</strong>ing only.<br />

UP<br />

BFGFVK and FGFVK<br />

Vent Kits Shown<br />

Figure 16 - Horizontal Termination Configuration<br />

for Rigid Venting<br />

Figure 18 - Horizontal Termination Using Flexible Venting<br />

10 105981