Page 4<br />

Regulatory Board 27.05.2009<br />

(c)<br />

(d)<br />

the site investigation results and the detailed risk assessment (2) and,<br />

based on these, an options appraisal and remediation strategy giving<br />

full details of the remediation measures required and how they are to<br />

be undertaken;<br />

a verification plan providing details of the data that will be collected in<br />

order to demonstrate that the works set out in (3) are complete and<br />

identifying any requirements for longer-term monitoring of pollutant<br />

linkages, maintenance and arrangements for contingency action.<br />

Any changes to these components require the express consent of the Local<br />

Planning Authority. The scheme shall be implemented as approved.<br />

(15) the development hereby permitted shall incorporate some or all of the<br />

following building design measures:-<br />

(a)<br />

(b)<br />

(d)<br />

(d)<br />

(e)<br />

(f)<br />

(g)<br />

the provision of gas impermeable membrane in a competent floor<br />

slab;<br />

above ground entry of services such that the floor slab is maintained<br />

intact;<br />

the sealing of service ducts and entry points against the ingress of<br />

landfill gases. It is advisable that service junctions into buildings<br />

should be through vented junction boxes;<br />

the provision of below floor venting by active or passive means.<br />

Passive means are by provision of air vents in outer walls to the below<br />

floor airspace. Air flow can be improved by adding vertical stacks<br />

incorporating a rotating cowl if required. Active venting is by means of<br />

positive ventilation systems. Air vents in passive systems must be<br />

kept free of any growth, a concentrate apron around the outer wall<br />

may secure this provision;<br />

the provision of methane and carbon dioxide gas monitors/alarms in<br />

below floor spaces and dead air spaces within the building;<br />

the provision of open hole windows in all occupied buildings;<br />

further measures to protect the site as a whole may include gas<br />

venting trenches and open grassed areas.<br />

The need for such measures shall be determined on the basis of existing data<br />

from current and previous monitoring of land fill gas by Kent County <strong>Council</strong>.<br />

Details of the building design measures shall be submitted to and approved<br />

by the Local Planning Authority before the commencement of the<br />

development.<br />

(16) floor levels of the units should be set a minimum of 300mm above local<br />

ground level;<br />