✻80 Device Programming Menu Mode<br />
STOP The "STOP" programming determines when and under what conditions the device will be deactivated.<br />
The following options are available:<br />
Upon Restore of a Zone List<br />
Restore Zone List: If a "ZONE LIST" is used as the “Stop” event, the device will de-activate when all the<br />
zones in that list restore from a previous fault, trouble, or alarm condition. This will occur regardless of<br />
what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" would normally only be<br />
used when a "ZONE LIST" is used to start the device.<br />
Upon a Zone Type or System Operation<br />
Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone (response) type or<br />
system operation action can be selected to de-activate the device.<br />
• If a specific "ZONE TYPE" is chosen, any zone of that response type that restores from a previous alarm,<br />
trouble, or fault condition will cause the device to de-activate.<br />
• If a "SYSTEM OPERATION" is chosen, that operation will cause the device to de-activate.<br />
During normal system operation, any devices may be manually started by keypad entry of: Code* + [#]<br />
+ 4 + “n;” or manually stopped by keypad entry of: Code* + [#] + 7 + “n,” where “n” = the device number to<br />
be controlled.<br />
* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more<br />
information.<br />
Programming Powerline Carrier Devices<br />
While in program mode, press ✻80 to enter Output Device Menu Mode. This mode is used to program<br />
all output devices used in the system. Refer to the output device table for ✻80 on the separate programming<br />
form when programming output devices.<br />
Note: The House ID of the Powerline Carrier Devices must be entered in data field ✻25.<br />
The prompts for ✻80 are as follows:<br />
80 Powerline Carrier Device Programming Main Menu prompt<br />
A 01<br />
Device Number--------------------- for entering the device number<br />
b<br />
Device Action ----------------------- for defining the action the device will perform when active<br />
C<br />
d<br />
Start Event Type ------------------ for assigning the event type to start the action<br />
Start Zone List --------------------- for assigning the zone list to start the action<br />
E<br />
Start Zone Type-------------------- for assigning the zone type to start the action<br />
F<br />
1A<br />
Stop Zone List ---------------------- for assigning the zone list to stop the action<br />
Stop Zone Type--------------------- for assigning the zone type to stop the action<br />
–30–