✻80 Device Programming Menu Mode<br />

STOP The "STOP" programming determines when and under what conditions the device will be deactivated.<br />

The following options are available:<br />

Upon Restore of a Zone List<br />

Restore Zone List: If a "ZONE LIST" is used as the “Stop” event, the device will de-activate when all the<br />

zones in that list restore from a previous fault, trouble, or alarm condition. This will occur regardless of<br />

what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" would normally only be<br />

used when a "ZONE LIST" is used to start the device.<br />

Upon a Zone Type or System Operation<br />

Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone (response) type or<br />

system operation action can be selected to de-activate the device.<br />

• If a specific "ZONE TYPE" is chosen, any zone of that response type that restores from a previous alarm,<br />

trouble, or fault condition will cause the device to de-activate.<br />

• If a "SYSTEM OPERATION" is chosen, that operation will cause the device to de-activate.<br />

During normal system operation, any devices may be manually started by keypad entry of: Code* + [#]<br />

+ 4 + “n;” or manually stopped by keypad entry of: Code* + [#] + 7 + “n,” where “n” = the device number to<br />

be controlled.<br />

* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more<br />

information.<br />

Programming Powerline Carrier Devices<br />

While in program mode, press ✻80 to enter Output Device Menu Mode. This mode is used to program<br />

all output devices used in the system. Refer to the output device table for ✻80 on the separate programming<br />

form when programming output devices.<br />

Note: The House ID of the Powerline Carrier Devices must be entered in data field ✻25.<br />

The prompts for ✻80 are as follows:<br />

80 Powerline Carrier Device Programming Main Menu prompt<br />

A 01<br />

Device Number--------------------- for entering the device number<br />

b<br />

Device Action ----------------------- for defining the action the device will perform when active<br />

C<br />

d<br />

Start Event Type ------------------ for assigning the event type to start the action<br />

Start Zone List --------------------- for assigning the zone list to start the action<br />

E<br />

Start Zone Type-------------------- for assigning the zone type to start the action<br />

F<br />

1A<br />

Stop Zone List ---------------------- for assigning the zone list to stop the action<br />

Stop Zone Type--------------------- for assigning the zone type to stop the action<br />

–30–