ADEMCO LYNXR Series Security Systems - Patriot Alarm Systems ...
ADEMCO LYNXR Series Security Systems - Patriot Alarm Systems ...
ADEMCO LYNXR Series Security Systems - Patriot Alarm Systems ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
✻83 Enhanced Sequential Mode<br />
IA<br />
IA<br />
zz<br />
LC<br />
Enroll mode<br />
0 = advance to next zone to be enrolled<br />
1 = enter now and proceed to SERIAL NUMBER<br />
prompt (1b).<br />
For 4 button keys (zones 26-29, 30-33, 34-37, &<br />
38-41) the serial number will be enrolled to all four<br />
buttons.<br />
If enrolling a key, the panel will emit a long beep<br />
when entering a 1 to indicate that the present key<br />
set up is invalid.<br />
Notes:(1) A valid template or key has 4 existing zones,<br />
each with a zone type, unique loop number.<br />
(2) If the display automatically advances to "1A"<br />
rather than "1b" the configuration of the key<br />
is not valid. At that point copy template,<br />
skip, or return are the only legal entries.<br />
2 = copy the previous serial number entry from<br />
the buffer.<br />
Notes:(1) Before you can copy a serial number you<br />
must first enter a serial number. If no serial<br />
is stored in the buffer and a copy is<br />
attempted the panel will emit a long beep<br />
indicating an invalid operation.<br />
(2) Not applicable for 4 button key zones 26-29,<br />
30-33, 34-37, & 38-41.<br />
3 = view existing serial number.<br />
Note: Only if “L” is displayed. If the “L” is not<br />
displayed the panel will emit a long beep.<br />
4 = copy the 4 button key template that has been<br />
set in zone numbers 26-29 (all zone parameters<br />
except serial numbers). (Only valid on<br />
zones 30-33, 34-37, & 38-41 that do not have<br />
serial numbers enrolled.)<br />
Notes:(1) Template acceptance is indicated by two<br />
beeps after copying.<br />
(2) A single long beep emitted when copying a<br />
indicates the template is not valid.<br />
9 = delete existing serial. Go to the (1A) prompt.<br />
For 4-button key, zones 26-29, 30-33, 34-37,<br />
& 38-41 have serial numbers. Delete all four<br />
at one time.<br />
Note: Only if “L” is displayed. If the “L” is not<br />
displayed the panel will emit a long beep.<br />
[✻] = advance to next zone to be enrolled<br />
[#] = return to previous prompt (A)<br />
Note: If “L” is displayed, the serial number for this transmitter has<br />
already been entered, however, it may still be confirmed,<br />
viewed or deleted.<br />
If the transmitter’s serial number has not been previously entered, you<br />
may enter the enroll serial number mode (1A) by entering “1”, or copy<br />
the last serial number that was entered by entering “2”.<br />
If the transmitter’s serial number has been previously entered, you may,<br />
view the present serial number by entering “3”. If view is selected each<br />
digit will be re-displayed, and the keypad will beep once for digits 1-6,<br />
and three times for the last digit. Once the serial number has been<br />
entered by either selecting a “1” or a “2”, you will return to this prompt<br />
with the “L” on the display. The serial number/loop number combination<br />
that was entered can be confirmed by getting two transmissions (fault<br />
and restore) from the RF or UR device or one transmission from the BR<br />
device. If a transmission is received that matches the serial number and<br />
loop number entered, the system will announce the Voice Descriptor for<br />
the loop followed by three beeps, and a “C” will be displayed indicating<br />
that the received serial number and loop number transmission has<br />
been confirmed to match. No further transmissions will be received.<br />
When confirming a 4 button key, only the serial number is confirmed,<br />
since it assumed that all loops are used. Pressing any key will allow a<br />
confirmation.<br />
*Long beep indicates illegal entries, or duplicate serial number/loop<br />
entry*<br />
When the last zone has been entered, the display will remain on that<br />
zone. To exit this mode and return to data field program mode, press 00<br />
at the ZONE NUMBER prompt.<br />
When all zones have been programmed, test each zone using the<br />
system’s Test mode. Do not use the Transmitter ID Sniffer mode for this,<br />
since it will only check for transmission of one zone on a particular<br />
transmitter, and not the zones assigned to each additional loop.<br />
For Zones 26-29, 30-33, 34-37, and 38-41 any loop can be used for RF<br />
enrollment. If enrolling via RF, it will be confirmed without additional<br />
transmissions.<br />
–34–