Selection<br />

12<br />

4.4 Field of application<br />

Field of application Illustration*<br />

Combustion<br />

chamber<br />

Industrial furnaces, open<br />

combustion chambers 4) A Open cone<br />

Industrial furnaces, open<br />

combustion chambers 4) B Cylindrical<br />

Industrial furnaces, open<br />

combustion chambers 4) C Tapered<br />

Industrial furnaces, open<br />

combustion chambers 4) D Flat fl ame quarl<br />

Crucible heating E Cylindrical<br />

Radiant tube heating<br />

1), 2), 3) F<br />

Hot-air generation<br />

1), 3) G<br />

Burner attachment<br />

tube with<br />

purging air bore<br />

holes<br />

Burner attachment<br />

tube with<br />

purging air bore<br />

holes, protective<br />

fl ame tube FPT<br />

Control<br />

High/Low<br />

Continuous<br />

High/Low<br />

High/Low/Off<br />

Continuous<br />

High/Low<br />

High/Low/Off<br />

Continuous<br />

High/Low<br />

High/Low/Off<br />

Continuous<br />

High/Low<br />

High/Low/Off<br />

Continuous<br />

Burner<br />

head type<br />

Max.<br />

capacity<br />

R 100 %<br />

Note<br />

Recommended for cold-air operating mode only,<br />

otherwise the nitric oxide values are too high<br />

R, H 100 % Normal to medium fl ow velocity<br />

R, H ca. 80 %<br />

K 100 %<br />

H 100 %<br />

On/High/Off H 100 %<br />

High/Low<br />

High/Low/Off<br />

Continuous<br />

R 100 %<br />

Medium to high velocity, capacity depending<br />

on the diameter<br />

In the case of continuous control, usage in<br />

the lower capacity range (≥ 40%) is restricted,<br />

depending on the burner<br />

The connection rating of the burners is<br />

chiefl y dependent on the capacity of the<br />

burner chamber.<br />

The connection rating of the burners is<br />

chiefl y dependent on the capacity of the<br />

burner chamber, usually < 2.5 W/cm². A<br />

draught blocker must be fi tted on the fl ue<br />

gas side.<br />

Protection of the fl ame from cooling is ensured<br />

by using a protective fl ame tube FPT<br />

(recommended for fl ow velocity of<br />

> 15 m/s)<br />

* See burner with attachment tube or burner quarl type.<br />

1) When using the burners in radiant tubes or in small combustion chambers, a trial under operating conditions is recommended. The burners must be<br />

secured gas-tight to the furnace or burner quarl by the furnace fl ange, so that a backfl ow of hot fl ue gases is avoided.<br />

2) The outlet diameter of the radiant tube must be reduced to the point where a pressure loss of approx. 10 mbar occurs at max. burner capacity.<br />

3) Only where the furnace temperature is < 600°C.<br />

4) For optimal operation, the burner quarl and the fl ame shapes are combined according to the fi eld of application (see Burners in burner quarls).<br />

<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 12.08