4.4 Field of application<br />
Field of application Illustration*<br />
Combustion<br />
chamber<br />
Industrial furnaces, open<br />
combustion chambers 4) A Open cone<br />
Industrial furnaces, open<br />
combustion chambers 4) B Cylindrical<br />
Industrial furnaces, open<br />
combustion chambers 4) C Tapered<br />
Industrial furnaces, open<br />
combustion chambers 4) D Flat fl ame quarl<br />
Crucible heating E Cylindrical<br />
Radiant tube heating<br />
1), 2), 3) F<br />
Hot-air generation<br />
1), 3) G<br />
Burner attachment<br />
tube with<br />
purging air bore<br />
holes<br />
Burner attachment<br />
tube with<br />
purging air bore<br />
holes, protective<br />
fl ame tube FPT<br />
Control<br />
High/Low<br />
Continuous<br />
High/Low<br />
High/Low/Off<br />
Continuous<br />
High/Low<br />
High/Low/Off<br />
Continuous<br />
High/Low<br />
High/Low/Off<br />
Continuous<br />
High/Low<br />
High/Low/Off<br />
Continuous<br />
Burner<br />
head type<br />
Max.<br />
capacity<br />
R 100 %<br />
Note<br />
Recommended for cold-air operating mode only,<br />
otherwise the nitric oxide values are too high<br />
R, H 100 % Normal to medium fl ow velocity<br />
R, H ca. 80 %<br />
K 100 %<br />
H 100 %<br />
On/High/Off H 100 %<br />
High/Low<br />
High/Low/Off<br />
Continuous<br />
R 100 %<br />
Medium to high velocity, capacity depending<br />
on the diameter<br />
In the case of continuous control, usage in<br />
the lower capacity range (≥ 40%) is restricted,<br />
depending on the burner<br />
The connection rating of the burners is<br />
chiefl y dependent on the capacity of the<br />
burner chamber.<br />
The connection rating of the burners is<br />
chiefl y dependent on the capacity of the<br />
burner chamber, usually < 2.5 W/cm². A<br />
draught blocker must be fi tted on the fl ue<br />
gas side.<br />
Protection of the fl ame from cooling is ensured<br />
by using a protective fl ame tube FPT<br />
(recommended for fl ow velocity of<br />
> 15 m/s)<br />
* See burner with attachment tube or burner quarl type.<br />
1) When using the burners in radiant tubes or in small combustion chambers, a trial under operating conditions is recommended. The burners must be<br />
secured gas-tight to the furnace or burner quarl by the furnace fl ange, so that a backfl ow of hot fl ue gases is avoided.<br />
2) The outlet diameter of the radiant tube must be reduced to the point where a pressure loss of approx. 10 mbar occurs at max. burner capacity.<br />
3) Only where the furnace temperature is < 600°C.<br />
4) For optimal operation, the burner quarl and the fl ame shapes are combined according to the fi eld of application (see Burners in burner quarls).<br />
<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 12.08