5 Project planning information<br />

5.1 Installation<br />

Installation position: any.<br />

Gas and air connection: can be rotated in 90° steps.<br />

Install and insulate the burner in order to avoid any overheating<br />

of the components during operation. Where applicable,<br />

purging air must be used to prevent ingress of aggressive<br />

gases and thermal overload of components.<br />

Purging air bore holes in the furnace flange area ensure cooling<br />

and stability in the case of combustion in small combustion<br />

chambers (for example radiant tubes).<br />

5.2 Recommended ignition transformer<br />

≥ 7.5 kV, ≥ 12 mA, e.g. TZI 7,5-12/100 or TGI 7,5-12/100.<br />

5.3 Nozzle-mixing burners<br />

Non-return gas valves are not required, since the burners are<br />

of the nozzle-mixing type.<br />

5.4 Flame control<br />

Flame control is performed using an ionisation electrode or<br />

optionally using a UV sensor.<br />

5.5 Hot air compensation<br />

In order to maintain the total connection rating constant in<br />

hot-air operating mode:<br />

1. Gas connection rating and gas pressure are reduced<br />

Total connection rating [%]<br />

100<br />

96<br />

90<br />

85<br />

80<br />

75<br />

0 50 100 150 200 250 300 350 400 450<br />

Combustion air temperature [°C]<br />

2. Air pressure is increased<br />

air pressure [%]<br />

200<br />

180<br />

160<br />

140<br />

120<br />

Gas connection rating<br />

Gas pressure<br />

100<br />

0 50 100 150 200 250 300 350 400 450<br />

Combustion air temperature [°C]<br />

<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 12.08