Pesticide Analyzer Reference - writeframeofmind.biz
Pesticide Analyzer Reference - writeframeofmind.biz
Pesticide Analyzer Reference - writeframeofmind.biz
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
About This Manual<br />
Analytical methods for food safety are used to screen and confirm positive pesticides results and they must be granted at least four identification points. For<br />
LC/MS and GC/MS detection methods using either electron ionization (EI) or chemical ionization (CI), two derivatives or the powerful MSMS or HRMS<br />
are available. For maximum productivity, the highly specific MSMS and HRMS methods are the preferred methods. Multi-residue pesticide methods are<br />
analytically challenging because of the diverse number of chemical structures and physical properties of the target analytes.<br />
Thermo Fisher Scientific provides methods and mass spectrometry instrumentation that complies with the strict international rules for screening and<br />
confirmatory analyses on either LC or GC separation for polar or less polar compounds using ion trap, triple quad or high resolution accurate mass MS<br />
instrumentation. The information and methodology in this document will show you how to analyze large numbers of pesticides using the TSQ Quantum GC<br />
mass spectrometer.<br />
About This Manual<br />
<strong>Pesticide</strong> analysis is a chromatographic challenge because there is a large variety of chemical compound groups that require high sample throughput and short<br />
run times. Sample preparation and clean-up is an integral step in pesticide analysis because there is a significant amount of sample matrix involved. Setting up<br />
the analytical method in a particular way can cut down on instrument maintenance and increase the robustness of the method. In this manual, we will<br />
describe how to set up a generic method for the multi-component GC-MS/MS analysis of over 500 pesticides.<br />
This method includes information about implementing the widely distributed QuEChERS sample preparation procedure, which is suitable for non- and<br />
low-fat sample material and can be employed for GCMS and LCMS. For GCMS extractions, an additional solvent exchange step is included in the method,<br />
which provides the extract in a GC-compatible solvent. For LCMS, the intermediate acetonitrile extract can be used directly.<br />
The GCMS method of choice for a multi-component pesticide analysis in matrix samples is the MS/MS technique using either ion trap or triple quadrupole<br />
mass spectrometers. The sample preparation, GC configuration and analytical method setup information is valid for ion trap detection with PolarisQ or ITQ.<br />
The MS part of this manual focuses on the use of the TSQ Quantum GC triple quadrupole mass spectrometer for creating a multiple reaction monitoring<br />
(MRM) analysis method.<br />
Thermo Scientific <strong>Pesticide</strong> <strong>Analyzer</strong> <strong>Reference</strong> 3