Fibre Optic Enclosures<br />
Protective Sleeves<br />
Protective Sleeve SM/2F..+2B<br />
N6297<br />
• The protective sleeve is an additional enclosure used for accommodating and protecting cable reserves and sleeves<br />
• Especially designed for underground laying<br />
• The split design makes it suitable for uncut cables<br />
• Can also be used for the storage of reserve lengths<br />
• 4 Entries for the installation of UF1 universal end fitting (cable entry) or double strain relief cone (blind plugs for spare entries)<br />
• Integrated support frame for the installation of OM1, OM1/1, OM1/2 and KM3 sleeves<br />
• Integrated support frame for the storage of 2 x 20m cable reserves<br />
• Installation point for an Electronic Marker System (EMS)<br />
• Entries 4x Universal end fitting LWL-UF1/R./KU/00<br />
Tube ø 40 or 50 mm<br />
Cable ø 10-20 mm<br />
• Tests<br />
Mechanical strength<br />
Load (5 min.) 18 kN, contact surface over the entire sleeve<br />
Impact (10 times) 6 kg guillotine, 90 cm fall, at the centre of the sleeve<br />
Impact (once) 7 kg sharp impact device, 80 cm fall, penetration depth < 20 mm at the centre of the sleeve<br />
Tightness with UF1 universal end fitting: mud-tight<br />
• Material<br />
Top and bottom: Glass-fibre reinforced polyester - yellow (similar to RAL 1018)<br />
Universal end fitting: POM<br />
Support frame: Powder-coated sheet steel, RAL 7035<br />
Screws and washers: Stainless steel<br />
• Weight: Approx. 27 kg<br />
• Scope of delivery: 1 Basic enclosure, 1 support frame, 1 copy of Instructions for Installation, 2 universal end fittings, 2 double strain relief cones, fixing<br />
material<br />
100<br />
SM